Technical data

2–45
Compaq HSZ80 Array Controller ACS Version 8.3 Maintenance and Service Guide
11. Press return to resume device port activity and restart the other controller. When
all port activity has restarted, FRUTIL displays the following:
PVA replacement complete.
Please wait . . .
If the other controller did not restart, press its reset button.
Field Replacement Utility terminated.
12. If the other controller did not restart, press its reset button.
13. Enable failover and re-establish the dual-redundant configuration with the
following command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem’s configuration from “this controller” to the
“other controller.”
14. Disconnect the PC or terminal from the controller’s maintenance port.