Technical data
2–46
Replacement Procedures
Replacing an I/O Module
Figure 2–6 shows a rear view of the BA370 enclosure and the relative location of the
six I/O modules (also referred to as ports). Figure 2–7 shows the six I/O modules and
the location of the connectors and securing screws. Use the following steps to replace
an I/O module:
NOTE: This procedure is not applicable for the M1 shelf.
An I/O module can be replaced in either a single-controller or a dual-redundant
controller configuration using this procedure.
Figure 2–6. I/O Module Locations in a BA370 Enclosure
Table 2–6 Description of I/O Modules in a BA370 Enclosure
Location Description
➀ Fans
➁ I/O Modules (6 each)
CXO6575A
2
1
4
3
6
5
2
1