Technical data
2–58
Replacement Procedures
Installing the New Member
Use the following steps to install a new member:
1. Insert a new disk drive that satisfies the replacement policy of the reduced
storageset into the PTL location of the failed disk drive.
NOTE: The controller automatically initializes the new disk drive and places it into
the spareset. As soon as it becomes a member of the spareset, the controller
automatically uses the new disk drive to restore the reduced RAIDset or mirrorset.
If initialization fails, the new disk drive is placed into the failedset.