NC3134 Fast Ethernet Server Adapter User Guide Third Edition (June 2007) Part Number 174846-00F Compaq Computer Corporation
Notice © 2001, 2007 Compaq Information Technologies Group, L.P. Compaq, the Compaq logo, and ProLiant are registered in U.S. Patent and Trademark Office. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States and other countries. Intel is a trademark of Intel Corporation in the United States and other countries. The Open Group and UNIX are trademarks of The Open Group in the United States and other countries.
Contents About This Guide Symbols in Text .......................................................................................................... v Compaq Technician Notes ......................................................................................... vi Where to Go for Additional Help............................................................................... vi Compaq Customer Support .......................................................................................
iv Compaq NC3134 Fast Ethernet Server Adapter User Guide Class B Equipment........................................................................................... A-3 European Union Notice........................................................................................... A-3 China Taiwan Notice .............................................................................................. A-3 Japanese Notice...........................................................................................
About This Guide This user guide can be used for reference when installing the Compaq NC3134 Fast Ethernet Server Adapter or one of its upgrade modules. WARNING: To reduce the risk of personal injury from electrical shock and hazardous energy levels, only authorized service technicians should attempt to repair this equipment. Improper repairs could create conditions that are hazardous.
vi Compaq NC3134 Fast Ethernet Server Adapter User Guide Compaq Technician Notes WARNING: Only authorized technicians trained by Compaq should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
About This Guide Compaq Customer Support You can reach Compaq automated support services 24 hours a day, every day at no charge. The services provide the most up-to-date information about Compaq products. You can access installation instructions, troubleshooting information, and general product information from the Compaq website. For comprehensive online support, refer to: http://www.compaq.com For international information, refer to: http://www.compaq.com/corporate/overview/world_offices.
viii Compaq NC3134 Fast Ethernet Server Adapter User Guide Calling the Compaq Support Line When you call the Compaq Support line, you must be at your server with your software running and the product documentation at hand.
Chapter 1 Introduction Overview The Compaq NC3134 Fast Ethernet Server Adapter is a second-generation, dual-port adapter that offers improved performance over earlier versions of the product. This improvement is due to the 64-bit/66MHz PCI-to-PCI bridge, as well as to the enhanced MAC silicon technology not previously available. The NC3134 adapter supports existing 10/100 Ethernet, 100FX, and 1000 SX/LX upgrade modules, which are listed in Table 1-1.
1-2 Compaq NC3134 Fast Ethernet Server Adapter User Guide Hardware Overview IMPORTANT: Two other devices, described separately in the Compaq NC3131 Fast Ethernet Server Adapter User Guide (available on the Compaq Website at www.compaq.com/support), are compatible with the NC3134 and the upgrade modules and drivers listed in this guide.
Introduction 1-3 Upgrade Modules The NC3134 adapter supports the following upgrade modules: NOTE: See the section titled “LED Indicator Descriptions” for descriptions of LED indicator functions. NC3135 Upgrade Module The NC3135 upgrade module has two RJ-45 dual-speed ports and associated LEDs indicating link, activity, and speed. Figure 1-2.
1-4 Compaq NC3134 Fast Ethernet Server Adapter User Guide NC3133, NC6132, and NC6133 Fiber Upgrade Modules The NC3133, NC6132, and NC6133 fiber upgrade modules each have one SC fiber port and LEDs indicating link and activity. Figure 1-4. NC3133, NC6132, and NC6133 fiber SC port and LED indicators LED Indicator Descriptions NC3134 and NC3135 LED Indicators The Compaq NC3134 adapter and NC3135 upgrade modules have two diagnostic LED indicators for each RJ-45 port.
Introduction 1-5 NC7132 LED Indicators The Compaq NC7132 upgrade module has four diagnostic LED indicators (see Figure 1-3). LED colors change with different link and activity (transmission/reception) speeds. Table 1-3 NC7132 Gigabit Upgrade Module LED Indicators LED Display Description Link/Speed Amber Link is established to the adapter at 10 Mb/s. The adapter is receiving power and the cable connection is good. Green Link is established to the adapter at 100 Mb/s.
Chapter 2 Installing the Upgrade Module and Adapter This chapter describes installation precautions, how to attach upgrade modules to the adapter, and how to install the adapter. It also describes how to attach the network cable and the loopback plugs. WARNING: To avoid the risk of personal injury or damage to the equipment, consult the Safety information and user documentation provided with your equipment before attempting the installation.
2-2 Compaq NC3134 Fast Ethernet Server Adapter User Guide Attaching the Upgrade Module The Compaq NC3134 Fast Ethernet Server Adapter design lets you attach an upgrade module. This increases the number of RJ-45 ports to four, in addition to adding one 100 Mb/s FX fiber port, one 1000 Mb/s fiber port, or one RJ-45 port that delivers 1000 Mb/s over twisted-pair (Gigabit over copper) cabling.
Installing the Upgrade Module and Adapter 5. Insert one hollow rivet through the adapter, and then through the extension bracket. When inserted properly, the lip of the hollow rivet is flush with the adapter and extends about 1/8 inch out of the bracket. 6. Insert one flat-headed pin into the hollow rivet until the head of the pin is flush with the lip of the hollow rivet. Flanges on the hollow rivet expand to hold the extension bracket tightly to the adapter. 7.
2-4 Compaq NC3134 Fast Ethernet Server Adapter User Guide Installing the Adapter in a Server Refer to the Compaq ProLiant™ documentation for the specific steps necessary to safely install a PCI card in your server. Figure 2-2. Installing the adapter in a server 1. If you have not already done so, and if the server is not PCI Hot Plug compliant, power down the server and unplug the power cord. 2. Remove both the server cover and the cover bracket from a PCI slot.
Installing the Upgrade Module and Adapter Connecting the Network Cable Network connections for the adapter and upgrade modules use UTP or fiber cable. See the sections “UTP Cable Specifications” and “Fiber Cable Specifications” in Appendix C for a description of each upgrade module and the cable and mode each module supports. Connecting UTP Network Cable The ports on the NC3134 adapter and the NC3135 10/100 and NC7132 upgrade modules use the following UTP connectors.
2-6 Compaq NC3134 Fast Ethernet Server Adapter User Guide Connecting and Using Loop-Back Plugs RJ-45 loop-back plugs are supplied in the adapter and upgrade module packages. A fiber loopback plug is available in a spare parts kit. Install these plugs in any unused RJ-45 or fiber port on the adapter or module, as described in the following section. If the plug is not installed, you may get a cable fault or reduced functionality on the adapter or module, depending on the operating system you are running.
Appendix A Regulatory Compliance Notices IMPORTANT: All of the following Regulatory Compliance Notices apply to the TX-based adapters and upgrade modules. For fiber adapters and fiber upgrade modules, only the European Union Notice applies. Federal Communications Commission Notice Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to provide an interference-free radio frequency spectrum.
A-2 Compaq NC3134 Fast Ethernet Server Adapter User Guide Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Regulatory Compliance Notices A-3 Canadian Notice (Avis Canadien) Class A Equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Class B Equipment This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
A-4 Compaq NC3134 Fast Ethernet Server Adapter User Guide Japanese Notice
Appendix B Electrostatic Discharge To prevent damage to the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage, observe the following precautions: ■ Avoid hand contact by transporting and storing products in static-safe containers.
Appendix C Specifications NC3134 Fast Ethernet Server Adapter Specifications Table C-1 NC3134 Fast Ethernet Server Adapter Specifications Specification Description Network Controller Chipset Intel 82559 MAC/PHY Data Transfer Method 64-bit/66MHz PCI, compatible with 64-bit/33MHz or 32-bit/33MHz Bus Master DMA Standards Supported IEEE 802.3x, 802.3u,802.3ad (static configuration mode only), 802.1p, and 802.1Q Dimensions 7.4 x 5.0 inches (L x W) 18.8 cm x 12.
C-2 Compaq NC3134 Fast Ethernet Server Adapter User Guide Upgrade Module Specifications Environmental and safety specifications for the upgrade modules are the same as those for the NC3134 Server Adapter, as shown in Table C-1. All other specifications are the same except where noted. NC3132 10/100 Upgrade Module Table C-2 NC3132 10/100 Upgrade Module Specifications Specification Description Network Controller Chipset Intel 82558 MAC/PHY Standards Supported IEEE 802.3x, 802.3u,802.1p, and 802.
Specifications C-3 NC6132 1000BASE-SX Upgrade Module Table C-4 NC6132 1000SX Upgrade Module Specifications Specification Description Network Controller Chipset Intel 82542 MAC Standards Supported IEEE 802.3z (1000BASE-SX) Connector and Distances See Table C-13 Dimensions 6.5 x 2.5 inches (L x W) 16.5 cm x 6.
C-4 Compaq NC3134 Fast Ethernet Server Adapter User Guide NC7132 1000BASE-T (Gigabit over Copper) Upgrade Module Table C-7 NC7132 Gigabit over Copper Upgrade Module Specification Description Network Controller Chipset Intel 82543GC MAC Standards Supported IEEE 802.3ab, 802.1p, 802.3z, 802.3u Connector and Distances One RJ-45, 100 meters on Category 5 (or better); for new installations, Category 5e is recommended Dimensions 6.2 x 3.
Specifications C-5 RJ-45 Pinouts and Crossover Function 10BASE-T, 100BASE-TX, and 1000BASE-T are keyed systems to differentiate between voice and data transmissions, in order to keep them separate over twisted-pair cable. The Ethernet standard also specifies that each cable segment implement a crossover function to connect the transmitter of one device to the receiver of a device at the other end, and vice-versa.
C-6 Compaq NC3134 Fast Ethernet Server Adapter User Guide 10/100 Crossover Pinouts When the crossover function is not provided within the hub or switch, you must implement the crossover through the twisted-pair media using the physical pinouts indicated in Table C-10.
Specifications C-7 Table C-11 Gigabit over Copper Pinouts Using Internal Crossover Pin Function Color Match Function Pin 1 BI_DA+ White/Orange BI_DA+ 1 2 BI_DA- Orange/White BI_DA- 2 3 BI_DB+ White/Green BI_DB+ 3 4 BI_DC+ Blue/White BI_DC+ 4 5 BI_DC- White/Blue BI_DC- 5 6 BI_DB- Green/White BI_DB- 6 7 BI_DD+ White/Brown BI_DD+ 7 8 BI_DD- Brown/White BI_DD- 8 Figure C-3 shows straight-through Gigabit over copper connector wiring to be used when the crossover func
C-8 Compaq NC3134 Fast Ethernet Server Adapter User Guide Gigabit over Copper External Crossover Pinouts When a crossover function is not provided by either the adapter or hub or switch, you must implement it through the twisted-pair media using the physical pinouts shown in Table C-12.
Specifications C-9 Fiber Cable Specifications To connect to the network, the NC3133, NC6132, and NC6133 upgrade modules use 100 BASE-FX, 1000 BASE-SX, or 1000BASE-LX fiber cable, respectively. Table C-13 and Table C-14 describe the fiber types, mode, cable size, and maximum distance specifications for the fiber upgrade modules. NOTE: All fiber upgrade modules use SC type connectors.