RAID Array 3000 Storage Subsystem
EK–SMCPQ–UG. C014-2
4.2 Installing the Upgrade
CAUTION
To prevent an electrical discharge from damaging the
SIMMs, always wear an ESD wrist or foot strap con-
nected to a suitable ground when handling the memory
modules.
NOTE
You can upgrade your firmware using the SCSI or net-
work connection methods. These methods provide the
fastest way to upgrade your firmware. To update your
controller’s firmware, proceed as follows.
4.2.1 Save Existing Configuration
NOTE
You must save the subsystem configuration using the
StorageWorks Command Console Client (SWCC) be-
fore performing the installation procedure. Otherwise,
the RAID controller may lose your configuration.
To save your current configuration:
Select the Storage pull-down menu from the Toolbar (see Figure 4-1), click on Con-
troller, select Configuration, and then Save.