Specifications

3-32 Compaq ProLiant 8500 Server Maintenance and Service Guide
200 299, Memory Test Error Codes
The 200 series of diagnostic error codes identifies failures with the memory subsystem.
Table 3-4
Memory Test Error Codes
Error Code Description Recommended Action
200-xx Invalid memory configuration. Reinsert memory modules in correct location and retest.
201-xx Memory machine ID test failed.
202-xx Memory system ROM checksum
failed.
1. Replace the system ROM and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
203-xx Memory write/read test failed.
204-xx Memory address test failed.
205-xx Walking I/O test failed.
206-xx Increment pattern test failed.
1. Replace the memory module and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
207-xx Invalid memory configuration -
check DIMM installation. DIMMs
installed have 8K refresh.
Replace DIMMs.
208-xx Invalid memory speed detected -
check DIMM installation. Slow
DIMMs may cause data loss.
Replace DIMMs with timing greater than 60 ns.
210-xx Random pattern test failed. 1. Replace the memory module and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
215 Non-functioning DC-DC converter
for processor X
Replace the DC-DC converter (Processor Power
Module).
300 399, Keyboard Test Error Codes
The 300 series of diagnostic error codes identifies failures with keyboard and system board
functions.
Table 3-5
Keyboard Test Error Codes
Error Code Description Recommended Action
301-xx Keyboard short test, 8042 self-test
failed.
302-xx Keyboard long test failed.
303-xx Keyboard LED test, 8042 self-test
failed.
304-xx Keyboard typematic test failed.
1. Check the keyboard connection. If disconnected,
turn off the computer, connect the keyboard, turn
on the power, and retest.
2. Replace the keyboard and retest.
3. Replace the system board and retest.