Specifications

Diagnostic Tools 3-55
Event List
The Event List displays the affected components and the associated error messages. Although
the same basic information displays, the format of the list may differ, depending on how you
view it: on the Integrated Management Display, from within Compaq Insight Manager, or using
the Compaq Survey Utility. An example of the format of an event displayed on the Integrated
Management Display is as follows:
**001 of 010**
---caution---
03/19/1997
12:54 PM
FAN INSERTED
Main System
Location:
System Board
Fan ID: 03
**END OF EVENT**
Event Messages
Table 3-22
Event Messages
Event Type Event Message Recommended Action
Machine Environment
Fan Failure System Fan Failure (Fan X, Location) Replace fan.
Fan Inserted System Fan Inserted (Fan X, Location) None
Fan Removed System Fan Removed (Fan X, Location) None
Fans Not Redundant System Fans Not Redundant Add fan.
Overheat Condition System Overheating (Zone X, Location) Check fans.
Main Memory
Correctable Error
threshold exceeded
Corrected Memory Error threshold passed
(Slot X, Memory Module X)
Replace the defective memory
module.
Corrected Memory Error threshold passed
(System Memory)
Replace the memory modules one
at a time (if more than one) and
retest the system after each
replacement.
Corrected Memory Error threshold passed
(Memory Module unknown)
Replace the memory modules one
at a time (if more than one).
Uncorrectable Error Uncorrectable Memory Error (Slot X,
Memory Module X)
Replace the defective memory
module.
Uncorrectable Memory Error (System
Memory)
Replace the defective memory
module.
Uncorrectable Memory Error (Memory
Module unknown)
Replace the memory modules one
at a time (if more than one) and
retest the system after each
replacement.
continued