QuickSpecs
NOTE:
NOTE:NOTE:
NOTE:
Please see the UPS and PDU cable matrix's on the HP Power Protection and
Management page. Under Power Cords, click on the "HP Power Cord Matrix" link.
That link will list cable descriptions, requirements, and specifications for UPS and PDU
units. Please see the following link:
www.hp.com/products/powercords
.
HP Rack Series
HP Rack SeriesHP Rack Series
HP Rack Series
HP Rack 10000 G2 Series
HP Rack 10000 G2 SeriesHP Rack 10000 G2 Series
HP Rack 10000 G2 Series
(Carbon/Graphite Metallic)
HP 10642 G2 Pallet Universal Rack
AF001A
HP 10642 G2 Shock Universal Rack
AF002A
HP 10642 G2 1200mm deep Shock Rack
AF092A
HP 10647 G2 1200mm deep Shock Rack
AF094A
NOTE:
NOTE:NOTE:
NOTE:
It is mandatory to use a shock pallet when shipping racks with equipment
installed.
NOTE:
NOTE:NOTE:
NOTE:
Please see the QuickSpecs for Technical Specifications and additional
information:
http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide)
NOTE:
NOTE:NOTE:
NOTE:
For additional information regarding Rack Cabinets, please see the following
URL:
http://www.hp.com/go/rackandpower
.
NOTE:
NOTE:NOTE:
NOTE:
HP ProLiant SL2x170z G6 models have two different rail kits to choose
from:
10U bulk rail kit - Used to fit in HP 10000 series racks
One 10U bulk rail kit will hold up to five z6000 chassis, thus ten
SL2x170z G6 server trays for a total of twenty system boards
2U rail kit - Used to fit in 3rd party racks or to sell one z6000 chassis at a time
One 2U rail kit will hold one z6000 chassis, thus two SL2x170z servers
for a total of four system boards
For additional information, please visit:
www.hp.com/go/rackandpower
.
NOTE:
NOTE:NOTE:
NOTE:
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks
provide enhanced airflow for maximum cooling, allowing these racks to be fully
loaded with servers using the latest processors.
CAUTION:
CAUTION:CAUTION:
CAUTION:
If a third-party rack is used, observe the following additional requirements
to ensure adequate airflow and to prevent damage to the equipment: Front and rear
doors: If your 42U server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to
permit adequate airflow (equivalent to the required 64 percent open area for
ventilation). Side: The clearance between the installed rack component and the side
panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION:CAUTION:
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-
spaces in the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
NOTE:
NOTE:NOTE:
NOTE:
Quick deploy rail system provides tool-free support for racks with square or
round mounting holes (including Compaq/HP 7000, 9000, 10000 G2 and HP
series), with an adjustment range of 24" - 36". The ambidextrous cable management
arm can be mounted on either the left or right side for improved cable management.
QuickSpecs
HP ProLiant SL2x170z Generation 6 (G6)
HP ProLiant SL2x170z Generation 6 (G6)HP ProLiant SL2x170z Generation 6 (G6)
HP ProLiant SL2x170z Generation 6 (G6)
Additional Options
DA - 13383 Worldwide — Version 22 — February 13, 2012
Page 27










