QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Overview HP ProLiant SL4545 Generation7 (G7) Server How are you going to scale out to petabytes with your current infrastructure? Big data, largely unstructured such as messages, images, readings from sensors, and GPS signals from cell phones, are growing at an exponential rate. The HP ProLiant SL4545 G7 Server solves the traditional structured database problems when dealing with big data.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Overview SL4545 G7 2x25 Model Front View: 1. Server Node 1 2. SFF 2.5" hard drives on node (2) 3. Hard drive backplane health LED 4. Storage UID 5. LFF hard drives 6. Server Node 2 7. Hard drive LED display boards 8. Node video connector (VGA port) 9. Node USB connectors (2) 10. Node power ON/Standby button and system power LED 11. Node health LED 12. Node ejection button 13. Node UID LED button SL4545 G7 3x15 Model Front View: 1. Server Node 1 2.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Overview 5. LFF hard drives connected to Server Node 1 (15) 6. Server Node 2 7. LFF hard drives connected to Server Node 2 (15) 8. Server Node 3 9. LFF hard drives connected to Server Node 3 (15) 10. Hard drive LED display boards 11. Node video connector (VGA port) 12. 13. 14. 15. 16. Node USB connectors (2) Node power ON/Standby button and system power LED Node health LED Node ejection button Node UID LED button 5.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Standard Features NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - Factory Integrated Models" section. Processor Eight-Core Processors One model of the AMD Opteron™ 4284 (3.0GHz/8-core/8MB/95W) Processor following per server node AMD Opteron™ 4274 HE (2.5GHz/8-core/8MB/65W) Processor Six-Core Processors AMD Opteron™ 4238 (3.3GHz/6-core/8MB/95W) Processor AMD Opteron™ 4226 (2.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Standard Features each server 1 PCIe 2.0 X8 X8 Low profile slot node *Indicates the number of physical electrical lanes running to the connector. NOTE: One PCIe 2.0 low profile expansion slot is enabled by HP Svr Storage Mezz to PCIe Option Kit 682632-B21 for adding one of the expansion options including an HP IO accelerator, networking options or external storage controller options. NOTE: Expansion Slot is hosted in the I/O Module.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Standard Features Hot Plug SFF SATA SSD 1.6TB 2 x 800GB NOTE: The node contains two SFF (2.5") hard drive bays on the front of the server. NOTE: The main storage section in the chassis has 60 LFF (3.5") hard drive bays and they can be populated with any combination of SAS, SATA, or SATA SSD drives to achieve desired performance. 2x25 Model - 25 LFF Drives per node Hot Plug LFF SAS 200.0TB 50 x 4TB Hot Plug LFF SATA 200.0TB 50 x 4TB Hot Plug SFF SATA 4.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Standard Features Compliance PCIe 2.0 Compliant WOL Support Microsoft® Logo certifications PXE Support USB 1.1 and 2.0 Compliant SMBIOS 2.6.1 Server Power Cords One 6' Highline (IEC-IEC) power cord ships standard NOTE: HP ProLiant SL servers are primarily connected to PDU's in data center racks so they ship standard with only a PDU power cord (416151-B21).
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Standard Features from HP, please visit our OS Support Site at: http://www.hp.com/go/ossupport and our driver download page: http://www.hp.com/support/SL4545G7. Graphics Form Factor On System Management ATI RN50 integrated with 32MB memory 4.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Standard Features reports. By providing the option of multiple local or shared repositories which can be easily updated from hp.com, HP SUM provides the tools to optimize stability and consistency throughout the company. While HP SUM and the SPP recommend the combinations of firmware and system software that HP has found to be the best practice, the application gives customers the flexibility to set their own specific baseline.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Optional Features HP Insight management HP Insight Control HP iLO Advanced HP Matrix Operating Environment HP Insight Control, a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, migrate, monitor, remote control, and optimize your IT infrastructure through a single, simple management console. For more information, see http://www.hp.com/go/insightcontrol.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Optional Features Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Service and Support Service and Support Standard Care HP Technology Services for Industry Standard Servers HP Technology Services delivers confidence, reduces risk and helps customers realize agility and stability. Connect to HP to help prevent problems and solve issues faster. Our support technology lets you to tap into the knowledge of millions of devices and thousands of experts to stay informed and in control, anywhere, any time.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Service and Support Get connected to HP to improve your support experience Parts and Materials Prevent problems with innovative, automated monitoring tools and proactive services. Combining Proactive Care Services with our remote support technology such as Insight Online provides you with expert advice and personalized, cloud-based automated IT support, helping to prevent unplanned down time and solve problems quickly.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Configuration Information - Factory Integrated Models NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on configurable product offerings and requirements. NOTE: Factory Integrated Models must start with a CTO Server.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Configuration Information - Factory Integrated Models HP I/O Modules HP Storage Controllers NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1600MHz or 1333MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Configuration Information - Factory Integrated Models Rack Adapter HP 13U FIO Rack Adapter Kit for 3X4.3U Chassis NOTE: Densely groups three SL4545 chassis into a 13U tall space. Order one per three chassis. The 0.66U spacer is not used when selecting this option.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Core Options NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information. HP Processors NOTE: Please choose Processor options for the second processor of each server node. Eight-Core Processors NOTE: All support up to 1600MHz DDR3 memory speeds. HP SL4545 Gen8 AMD Opteron™ 4274HE (2.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Core Options desired performance and up to a total of 2 SFF 2.5" hard drives per server node from the following options for OS, boot or additional storage purposes. NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Core Options Wty Solid State Drive HP 200GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty Solid State Drive HP 100GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty Solid State Drive 6G SATA ME Hot Plug LFF (3.5-inch) Enterprise Mainstream Solid State Drives HP 800GB 6G SATA Mainstream Endurance LFF 3.5-in SC Enterprise Mainstream 3yr Wty Solid State Drive HP 400GB 6G SATA Mainstream Endurance LFF 3.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options High Performance Clusters HP Cluster Management Utility HP Insight Cluster Management Utility 1yr 24x7 Flexible License HP Insight Cluster Management Utility 3yr 24x7 Flexible License NOTE: These part numbers can be used to purchase one certificate for multiple licenses and support with a single activation key. Each license is for one node (server).
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options HP Storage Controllers HP Power Cords SAS Controllers Smart Array P421 Controller HP Smart Array P421/1GB FBWC 6Gb 2-ports Ext SAS Controller HP Smart Array P421/2GB FBWC 6Gb 2-ports Ext SAS Controller Optional Upgrades HP 12in Super Capacity Option for Smart Array HP 1GB P-series Smart Array Flash Backed Write Cache HP 2GB P-series Smart Array Flash Backed Write Cache NOTE: Due to cabling requirements, the HP 12in Super Cap is a r
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options HP Tape Backup HP Tape Storage Systems HP C13 - Nema 5-15P US/CA 110V 10Amp 1.83m Power Cord HP C13 - IS-1293 IN 240V 6Amp LV 2.0m Power Cord HP C13 - IRAM -2073 AR 250V 10A 2.5m Power Cord HP C13 - C14 WW 250V 10Amp Flint Gray 2.0m Jumper Cord AF556A AF562A AF558A AF573A NOTE: For the complete range of tape drives, autoloaders, libraries and media see: http://www.hp.com/go/tape.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options HP R7KVA 4U IEC-32A High Voltage INTL Uninterruptible Power System NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/14110_div/14110_div.html (Worldwide) NOTE: For additional information on HP Uninterruptible Power Systems please go to: www.hp.com/servers/rackups. NOTE: For additional information on sizing your server, please reference: http://www.upssizer.com.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options Power Distribution Units HP 2.8kVA 120 Volt L5-30 Input (12xNEMA 5-20R)NA/JP Monitored PDU (mPDU) HP 3.6kVA 200-240 Volt Detachable C20 Input (12xC13) WW Monitored PDU HP 4.9kVA 208 Volt L6-30 Input (12xC13) NA/JP Monitored PDU HP Remote Monitored Power Distribution Unit: Half Height Version HP 3.6kVA 200-240 Volt Detachable C20 Input (16xC13) WW Monitored PDU HP Remote Monitored Power Distribution Unit: Mid Height Version HP 4.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options Distribution Unit HP 17.3kVA 24A 415V Three Phase 12 Outlet Core NA/JP Intelligent Power Distribution Unit HP 22kVA 32A 400V Three Phase 12 Outlet Core INTL Intelligent Power Distribution Unit iPDU Kits with Standard Extension Bars HP 4.9kVA 24A Single Phase NA/JP Intelligent Modular Power Distribution Kit HP 8.6kVA 24A Three Phase NA/JP Intelligent Modular Power Distribution Kit HP 7.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options HP TFT7600 G2 KVM Console Rackmount Keyboard JP Monitor HP TFT7600 G2 KVM Console Rackmount Keyboard RU Monitor HP TFT7600 G2 KVM Console Rackmount Keyboard Intl Monitor HP TFT7600 G2 KVM Console Rackmount Keyboard US TAA Monitor NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13731_div/13731_div.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Additional Options Service HP 3 year 24 hour 24x7 Call to Repair SL454x 1 Node Chassis Hardware Support HP 3 year 24 hour 24x7 Defective Media Retension SL454x 1 Node Chassis Hardware Support HP 3 year 6 hour 24x7 Call to Repair SL454x 1 Node Chassis Hardware Support HP 3 year6 hour 24x7 Defective Media Retension SL454x 1 Node Chassis Hardware Support HP 3 year 6 hour 24x7 SL454x 1 Node Chassis Call to Repair Proactive Service HP 3 year 6 hour24x7 Defe
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Memory HP ProLiant SL4545 G7 server NOTE: Memory configurations listed do not apply to "Factory Integrated Models". NOTE: Chart does not represent all possible memory configurations.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Memory References to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc. DIMM slot and configuration diagrams Basic memory slot & population diagram Chnl 1 Population order; start with "A" first, "B" second, "C" third, etc.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Memory Chnl 2 4 5 6 B; 16GB DIMM F; 16GB DIMM D; 16GB DIMM 4 5 6 B; 16GB DIMM F; 16GB DIMM D; 16GB DIMM Chnl 2 NOTE: Capacity references are rounded to the common Gigabyte values. 1GB = 1024MB 2GB = 2048MB 4GB = 4096MB 8GB = 8192MB 16GB = 16384MB DDR3 memory options part number decoder Following are memory options available from HP: HP Memory NOTE: Please choose memory options for socket 2 of each server node.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Memory Low Voltage Memory Kit HP 16GB (1x16GB) Dual Rank x4 PC3U-10600R (DDR3-1333) Registered CAS-9 Ultra Low Voltage Memory Kit c04123203-DA – 14407 Worldwide — Version 11 — November 1, 2014 647881-B21 Page 32
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Storage 1x60 Model 1-2 2 x SFF SATA/SATA SDD Hot Plug Hard Drive Bays 1-30 30 x LFF SATA/SAS/SDD Hot Plug Hard Drive Bays Controller Port 1i 1-30 30 x LFF SATA/SAS/SDD Hot Plug Hard Drive Bays Controller Port 2i 2x25 Model 1-2 1-2 2 x SFF SATA/SATA SDD Hot Plug SFF Hard Drive Bays for server node 1 2 x SFF SATA/SATA SDD Hot Plug SFF Hard Drive Bays for server node 2 1-25 25 x LFF SATA/SAS/SDD Hot Plug Hard Drive Bays for server node 1 1-25 25 x LF
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Storage 1-2 2 x SFF SATA/SATA SDD Hot Plug SFF Hard Drive Bays for server node 2 1-2 2 x SFF SATA/SATA SDD Hot Plug SFF Hard Drive Bays for server node 3 1-15 15 x LFF SATA/SAS/SDD Hot Plug Hard Drive Bays for server node 1 1-15 15 x LFF SATA/SAS/SDD Hot Plug Hard Drive Bays for server node 2 1-15 15 x LFF SATA/SAS/SDD Hot Plug Hard Drive Bays for server node 3 Maximum Storage Capacity - 1x60 Model Internal 2TB (2 x 1TB SATA SFF) (2 SFF Drive Cage) I
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Technical Specifications System Unit Chassis Dimensions (H x W x D) 7.47 x 17.45 x 35.34in (18.96 x 44.33 x 89.97cm) NOTE: Rack chosen is required to have 1200mm to provide space for cable management arm at the rear of the chassis and host PDU in the rear of the rack Weight Maximum 220lb (99.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Technical Specifications Altitude Acoustic Noise Emissions Classification (EMC) wet bulb temperature, non-condensing. Operating 10,000 ft (3048 m). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 1500 ft/min (457 m/min). Non-operating 30,000 ft (9144 m). Maximum allowable altitude change rate is 1500 ft/min (457 m/min).
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Technical Specifications Connector Cable Support QSFP - IB SFP+ - 10Gb/s Ethernet IB: 10Gb/s NOTE: IB supported with addition of HP IB Enablement Kit HP copper and optical IB cables HP copper and optical SFP+ cables HP Smart Array P420i Controller Dimensions Disk Drive and Enclosure Interface - Transfer rate SAS Connectors Cache Memory Speed Server Interface SAS Speed Cache Memory Logical Drives Supported Host Memory Addressing RAID Support Enviro
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Summary of Changes Date 01-Nov-2014 Action Changed Description of Change: Service and Support section updated 09-Jun-2014 Version History From Version 10 to 11 From Version 9 to 10 Changed 13-Dec-2013 From Version 8 to 9 Changed Hard Drives, Networking, Insight Control, Tape Backup, and Basic and Remote Monitoring Power Distribution Units were revised.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Summary of Changes section. Configuration Information: Updated Notes at beginning of section, Step 1, Step 1A, Step 2 and Step 3. Core Options: Updated HP Processors, HP Memory, HP Hard Drives, HP Networking and HP InfiniBand sections. Additional Options: HP Insight Software and HP Tape Backup sections. Memory: HP Memory section.
QuickSpecs HP ProLiant SL4545 Generation7 (G7) Server Summary of Changes For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.