Inability to Upgrade the Board’s Firmware
If you attempt to upgrade the firmware of the Remote Insight Lights-Out
Edition and the board does not respond or does not accept the firmware
upgrade, you must force the ROM upgrade procedure by changing the default
switch settings of SW3 as shown in Table 7-2.
Table 7-2
Switch Settings (SW3)
Switch Default Force ROM Upgrade
1 OFF ON
2 OFF ON
3 OFF OFF
4 OFF OFF
Upgrade the firmware of the Remote Insight Lights-Out Edition using a
ROMPaq diskette. When the firmware upgrade is complete, return the
switches to the default position.
Interpreting LED Error Codes
The LED indicators on the front of the Remote Insight Lights-Out Edition
board (with the LED indicators on top) have the following assignments:
FB 7 6 5 4 3 2 1 0
During the initial boot of the Remote Insight Lights-Out Edition, the LED
indicators will flash randomly. After the board has booted, the FB LED will
flash every second. The LED indicators (1 through 7) will light up after the
system has booted to indicate a hardware failure. If a hardware failure is
detected, reset the Remote Insight Lights-Out Edition board. See the
“Resetting the Remote Insight Lights-Out Edition Board” section of this
chapter.