User guide
Troubleshooting the Remote Insight Lights-Out Edition 7-9
Compaq Confidential – Need to Know Required
Writer: James Parish Project: Compaq Remote Insight Lights-Out Edition User Guide Comments:
Part Number: 159206-005 File Name: h-ch7 Troubleshooting the Remote Insight Lights-Out Edition.doc Last Saved On: 7/10/01 4:30 PM
Event Log Entries
Table 7-3 lists Event Log Entries and explanations to help you troubleshoot
the Remote Insight Lights-Out Edition board. In the table, USER, #, and IP
ADDRESS are used to designate that a specific user, number, or IP address is
displayed, as appropriate.
Table 7-3
Event Log Entries
Event Log Display Event Log Explanation
Server power failed Displays when the server power fails
Browser login: IP address Displays the IP address for the browser that
logged in
Server power restored Displays when the server power is restored
Browser logout: IP address Displays the IP address for the browser that
logged out
Server reset Displays when the server is reset
Failed Browser login - IP Address: IP
address
Displays when a browser login fails
Remote Insight Self Test Error: # The Remote Insight board has failed an
internal test. The probable cause is a
critical component has failed. Further use
of this board is not recommended.
Remote Insight Board reset Displays when the board is reset
On-board clock set; was #:#:#:#:#:# Displays when the on board clock is set
Server logged critical error(s) Displays when the server logs critical
errors
Event log cleared by: USER Displays when a user clears the event log
Keyboard cable disconnected Displays when the keyboard cable is
disconnected
Keyboard cable connected Displays when the keyboard cable is
connected
Remote Insight Board reset to factory
defaults
Displays when the board is reset to the
default settings
Remote Insight Board reset Displays when the board is reset
continued