Compaq Lights-Out DOS Utility D-5
The /help command has a return message similar to the following:
CPQLODOS: RILOE bootstrap config utility.
(C) 2001 Compaq Computer Corporation
Version 1.0
CPQLODOS {cmds}
where cmds are:
/detect - Detect the RIB card.
/help - Display this message.
/reset_riloe - Reset the RILOE card.
/get_status - Get RILOE status.
/get_hostinfo - Discover RILOE host info.
/get_nicconfig - Discover RILOE network config.
/get_dhcpconfig - Discover DHCP config.
/write_xml = - Write settings to an XML file.
/load_xml = - Read settings from an XML file.
/verify_xml = - Validate an XML file syntax.
/p - Pause on error.
/log = - Capture output to a log file.
/min_fw = - Do not run on a firmware less than (default is 2.30).
Return Codes:
0 - Success
1 - Failure
/detect
The /detect command determines if a RILOE board is installed and returns a
success or failure error code. The /detect command returns a code of “0” if the
detection is successful, or a “1” if the detection was unsuccessful.
/get_status
The /get_status command obtains the RILOE board status displays the
following information:
Firmware version and date
RILOE board serial number
Current RILOE board time and date
RILOE board type
Remote Console session warning, if one is in progress