User guide

4-8 Compaq Remote Insight Lights-Out Edition User Guide
Compaq Confidential Need to Know Required
Writer: James Parish Project: Compaq Remote Insight Lights-Out Edition User Guide Comments:
Part Number: 159206-005 File Name: e-ch4 Configuring the Remote Insight Lights-Out Edition.doc Last Saved On: 7/10/01 4:16 PM
Novell NetWare 4.2
1. During the post-installation process, the NetWare installation incorrectly
attempts to load the MEGA4_XX.HAM driver.
2. Remove the MEGA4_XX.HAM driver from the disk and CD-ROM
drivers list during the Choose the Server Drivers interview.
3. If you missed the opportunity to remove the driver, ignore the error
statement when the install program tries to install the driver and edit the
STARTUP.NCF file and remove MEGA4_XX.HAM driver when the
installation is complete.
4. After the installation of NetWare completes, add the following lines to
the AUTOEXEC.NCF file:
LOAD CPQHLTH.NLM
LOAD CPQRI.NLM
NOTE: The cpqhlth.nlm driver should come before cpqri.nlm in the load order. This will
ensure that the appropriate server error log will be copied to the Remote Insight
Lights-Out Edition board during initialization.
5. At the end of the installation, refer to the instructions in the System
Configuration Utility Setup Using the F10 Keysection in this chapter
to configure the Remote Insight Lights-Out Edition board.
Novell NetWare 5
1. During the post-installation process, the NetWare installation incorrectly
attempts to load the MEGA4_XX.HAM or I20PCI.HAM driver.
2. Select F10=Continue-no selection to continue the installation without
loading either driver.
3. If you missed the opportunity to remove the driver, edit the
STARTUP.NCF file and remove MEGA4_XX.HAM driver when the
installation is complete.
4. During the post-installation interview, install the Compaq Management
Agent for Servers on the Additional Products and Services screen.
5. Select Compaq Remote Insight Management Agents on the NSSD
Options screen.
6. At the end of the installation, refer to the instructions in the System
Configuration Utility Setup using the F10 keysection in this chapter to
configure the Remote Insight Lights-Out Edition board.