3. Start SNMP and agent processes using the following commands:
/etc/rc.d/init.d/snmpd start
/etc/rc.d/init.d/cmafdtn start
/etc/rc.d/init.d/cmasvr start
/etc/rc.d/init.d/cmastor start
/etc/rc.d/init.d/cmanic start
Optimized Performance for Remote
Console
Starting with firmware version 2.31, the remote console application has been
optimized for greater performance.
The remote console will operate with greater or lesser success depending on
the settings of the remote server. Ideally, the remote server operating system
resolution should be the same resolution, or smaller, than the browser
computer. The higher the resolution of the remote server, the slower the
overall performance. For best results, use the following settings.
Browser Settings
Use the following browser settings to optimize performance:
Display Properties Setting
GSelect an option greater than 256 video colors.
GSelect a greater screen resolution than the remote servers screen
resolution.
Remote Console
GSelect Remote Console (Full) to maximize the viewable area.
GIn Settings, select the operating system to match the servers
operating system and the character set to match the remote servers
character set. For Red Hat Linux 6.2 and 7.0, SCO UnixWare 7.x,
and SCO OpenServer 5.x, you would select the Unix operating
system.