QuickSpecs

3.
with the factory integration part number.
Compatible with EVAs (EVA4100/6100/8100 arrays only). Without a loop switch pair,
up to four drive enclosures are supported with each pair of HSV200B controllers
(EVA4100, EVA4100 Starter Kits, EVA4100/6100 Controller Assembly). An HSV200B
controller with a loop switch pair supports 1to 8 M5314C Drive Enclosures.
NOTE:
NOTE:NOTE:
NOTE:
Addition of the loop switch pair to an HSV200B controller pair (with 1 to 8
drive enclosures) creates an EVA6100.
Up to 18 drive enclosures are supported with each pair of HSV210B (EVA8000) with 4
loop switches.
M5314C FC Drive Enclosure
The M5314C is a 3U dual-redundant FC Loop 14-bay disk enclosure with mounting
hardware, and the necessary copper FC cables for connecting to an HSV200B and
HSV210B Controller pair.
NOTE:
NOTE:NOTE:
NOTE:
Minimum of 8 disk drives, of any size, are required per Fibre Channel or FATA
drive types
*0D1 will appear after this part number on your sales order when factory integration is
indicated.
Dual FC Loop
Dual FC LoopDual FC Loop
Dual FC Loop
Switch Option
Switch OptionSwitch Option
Switch Option
The EVA Dual FC Loop Switch Option must be field installed to an EVA4x00 when
upgrading to an EVA6x00. The EVA8x00 FC Loop Switch Option is used when
upgrading and EVA8x00 2C2D beyond 4 disk enclosures
EVA Dual FC Loop Switch Option for EVA6x00
Contains two FC loop switches, mounting hardware and cables.
AD557B
*
EVA8x00 FC Loop Switch Option
Contains 4 FC loop switches, mounting hardware and cables
AD553B
*
Enterprise Virtual Array
Enterprise Virtual ArrayEnterprise Virtual Array
Enterprise Virtual Array
Racking for Expansion
Racking for ExpansionRacking for Expansion
Racking for Expansion
The EVA customers have the option to mount supported devices in the rack used for
EVA8x00 expansion.
EVA 42U HP 10000 G2 Series Rack
Power requirements vary based on the equipment to be placed in the rack and the
country power supply. Options are:
AF002A
HP PDU Pivot Kit
Used when expanding an existing EVA8x00 to 2C12D. It may also be used to reclaim
2U of space in a 10000 G2 Series Rack with other EVA configurations. EVA8000
2C12D configured in the factory include the PDU Pivot kit as part of the standard
configuration.
AG730A
Modular PDU 24A Low Volt, NA/JPN
252663-D71
#0D2
Modular PDU 24A HV, NA/JPN
252663-D72
#0D2
Modular PDU 32A HV, INTL
252663-B31
#0D2
NOTE:
NOTE:NOTE:
NOTE:
#0D2 feature code designates the PDU is mounted horizontally in the bottom
of the rack on real rail, above any UPS, and occupies 1U EIA space
Low voltage PDU 252663-D71 requires additional power distraction module
AF500A. (1) AF500A supports 2 PDUs
AF500A
QuickSpecs
HP StorageWorks 6100/8100 Enterprise Virtual Arrays
HP StorageWorks 6100/8100 Enterprise Virtual ArraysHP StorageWorks 6100/8100 Enterprise Virtual Arrays
HP StorageWorks 6100/8100 Enterprise Virtual Arrays
Configuration Information and Configuration Rules
DA - 12745 Worldwide — Version 11 — September 14, 2009
Page 40