Technical data

6. Install disks into storage shelves.
7. Connect a terminal to the maintenance port on one of the HSG80
controllers. You need a local connection to configure the controller for
the first time. The maintenance port supports serial communication
with the following default values:
9600 bits/sec
8 data bits
1 stop bit
No parity
8. Connect the RA8000 or ESA12000 to the power source and apply power.
____________________ Note _____________________
For the HSG80 to see the connection to the KGPSAs, the
KGPSA host bus adapters must be cabled to the switch or
hub, with the system power applied before you turn power on
to the RA8000/ESA12000.
9. If an uninterruptible power supply (UPS) is used instead of the external
cache battery, to prevent the controller from periodically checking the
cache batteries after power is applied, enter the following command:
HSG80> set this CACHE_UPS
____________________ Note _____________________
Setting the controller variable CACHE_UPS for one controller
sets it for both controllers.
10. From the maintenance terminal, use the show this and show other
commands to verify that controllers have the current firmware version.
See the Compaq StorageWorks HSG80 Array Controller ACS Version 8.5
CLI Reference Guide for information on upgrading the firmware.
11. To ensure proper operation of the HSG80 with Tru64 UNIX and
TruCluster Server, set the the controller values as follows. Note that the
port topology setting of fabric is specific to fabric configurations.
HSG80> set nofailover
1
HSG80> clear cli 2
HSG80> set this mirrored_cache 3
HSG80> set multibus copy = this 4
HSG80> clear cli 5
HSG80> set this port_1_topology = offline 6
HSG80> set this port_2_topology = offline 6
Using Fibre Channel Storage 6–43