Product specifications

Infortrend
4-26
Figure 4-42: Drive Space Allocated to the Previous
Partition
As illustrated above, the capacity of the deleted partition will be added to
the previous partition.
WARNING!
Whenever a partition is changed, it is necessary to reconfigure all
host LUN mappings. All data kept in the partition and the host LUN
mappings will be removed with any partition change.
4.10.3 Assigning a Name to a Logical Drive
Naming can help identify different arrays in a multi-array configuration.
This function is also useful in special situations. For example, when one or
more logical drives have been deleted, the array indexing is changed after
system reboot. The second logical drive might become the first on the list.
Figure 4 - 43: Name a Logical Drive Page
Choose the logical drive for which you wish to assign a name, then press
[ENTER]. Choose logical drive name, then press [ENTER] again. The
current name will be displayed. You may now enter a new name in this
field. Enter a name, then press [ENTER] to save the configuration. The
maximum number of characters for a logical drive name is 14.
4.10.4 Rebuilding a Logical Drive
If there is no spare drive in the system, a failed drive should be
immediately replaced by a drive known to be good. Once the failed drive is
replaced, the rebuild process can be manually initiated.