Specifications
SCSI to SATA RAID Subsystem | Administrator’s Manual Terminal Operation | en 119 
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
7.12.2 Adding an ID 
Fig. 7.55 Add ID Screen
Press [ENTER] on one of the existing IDs. Choose Add Channel ID, and then choose to assign 
an ID. A list of host IDs will appear. Choose an ID. DO NOT choose an ID used by another 
device on the same channel. 
7.12.3 Deleting an ID
Fig. 7.56 Delete ID Screen
Choose the host bus ID you wish to delete. Choose Delete Channel ID. The dialog box “Delete 
ID#?” will appear. Select Yes, then press [ENTER] to confirm.
i
NOTICE! 
• Every time you change a channel ID, you must reset the subsystem/controller for the 
changes to take effect.
• Multiple target IDs can be applied to a host channels while each drive channel has only 
one ID. 
• At least one controller’s ID has to be present on each channel bus.