Specifications
144 en | Enclosure Management SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
When enabled, each of the above conditions forces the controller/subsystem to adopt the 
write-through caching mode. When the fault condition is corrected, the controller/subsystem 
automatically restores the previous caching mode. 
Fig. 9.2 Controller Write-Through Alert
Note that the temperature thresholds refer to those set for both sensors on the RAID control-
ler boards and those placed within the subsystem enclosure. In terms of the controller tem-
perature, board 1 refers to the main circuit board and board 2 refers to the second-level I/O 
board or the daughter card. If any of the threshold values set for any sensor is exceeded, the 
trigger automatically applies. 
i
NOTICE! 
If a battery is not installed in your RAID subsystem, the “BBU Low or Failed “ option should be 
disabled.