Specifications
SCSI to SATA RAID Subsystem | Administrator’s Manual RAID Planning | en 29 
Bosch Security Systems F.01U.027.802 | V1 | 2006.11
2.4 Tunable Parameters
Fine-tune the subsystem and the array parameters for your host applications. Although the 
factory defaults guarantee the optimized operation, you may refer to the table below to facili-
tate tuning of your array. Some of the performance and fault-tolerance settings may also be 
changed later during the preparation process of your disk array.
Use this table as a checklist and make sure you have each item set to an appropriate value.
 (1) Parameters that should be configured at the initial stage of system configuration
(2) Parameters that can be changed later
(3) Non-critical
Table 2.1 Controller Parameter Settings 
User-Defined 
Parameters
Default Alternate Settings
Fault Management:
(1) Automatic Logical 
Drive Rebuild - Spare 
Drive
Enabled when 
Spare Drive is 
available
RAID 1 + Local Spare
RAID 3 + Local Spare
RAID 5 + Local Spare
Global Spare
(1) S.M.A.R.T.  Detect Only Disabled
Perpetual Clone
Clone + Replace
(3) Clone Failing Drive Manual func-
tion
Replace After Clone
Perpetual Clone
(1) Rebuild Priority Normal Low
Improved
High
(1) Verification on 
Write
Disabled On LD Initialization
On LD Rebuild 
On Normal Drive Writes
(3) SDRAM ECC Enabled Disabled
(2) Periodic Cache 
Flush
Disabled Continuous to 10 minutes
(1) Event Notification Reports to user 
interface and 
onboard alarm
Over SNMP Traps
Over Java-Based Management Software
(2) Periodic Auto-
Detect Failure Drive 
Swap Check Time
5 Disabled, 5 to 60 seconds
(2) Periodic Drive 
Check Time
30 Disabled, 0.5 to 30 seconds
(2) Rebuild Priority normal Low, normal, improved, high