Specifications
80 en | LCD Keypad Operation SCSI to SATA RAID Subsystem | Administrator’s Manual
F.01U.027.802 | V1 | 2006.11 Bosch Security Systems
5.15 Drive Utilities
From the “View and Edit Drives” menu, select the drive that the utility is to be performed on; 
then press ENT. Select “Drive Utilities; then press ENT. Choose “Read/Write Test”.
These options are not available for drives already configured in a logical configuration, and can 
only be performed before a reserved space is created on a drive. 
5.15.1 Drive Read/Write Test
From the “View and Edit Drives” menu, select a new or used drive that the utility is to be per-
formed on; then press ENT. Select “SCSI Drive Utilities;" then press ENT. Choose “Read/Write 
Test” and press ENT. 
Press the up or down arrow keys to select and choose to enable/disable the following 
options: 
1. Abort When Error Occurs 
2. Drive Test for - Read Only/Read and Write. 
3. Execute Drive Testing
When finished with configuration, select "Execute Drive Testing" and press ENT to proceed.
The Read/Write test progress will be indicated as a percentage. 
You may press ESC and select "Read/Write Test" later and press or V to select to "View Read/
Write Testing Progress" or to "List Current Bad Block Table." If you want to stop testing the 
drive, select "Abort Drive Testing" and press ENT to proceed.