Operating instructions
remote is on
C/F D
When high/active, indicates that Cp3xxx
display is in degrees C
Spa_Heater_On D
Real feedback indicating heat source for
spa is on
Pool_Heater_On D
Real feedback indication heat source for
pool is on
Freeze_Mode D
When high/active, indicates LX-3xxx has
entered protective freeze mode
Solar_Present D
When high/active, will allow user to select
solar as a heat method (if Model 3830,
indicates pool solar present)
Solar_State D
When high/active, indicates solar is on (if
Model 3830, this is the pool solar state)
Heater_State D
When high/active, indicates heater is on (if
Model 3830, this is the pool heater state)
Service_Mode D
When high/active all controller commands
are ignored and only local switches at the
LX-3xxx equipment pad are honored
Solar_Spa_Heater_On D
When high/active, indicates solar spa
heater is on
Solar_Pool_Heater_On D
When high/active, indicates solar pool
heater is on
Spa_Solar_Present D
When high/active, will allow user to select
solar as the heat method for the spa
Cleaner_Delay_On D
Indicates that the cleaner is being forced
off by the delay function to allow water to
fill the pipes
Pool_Delay_On D
Indicates that the pump is being forced on
by the delay function to allow the heater
to cool down
Spa_Delay_On D
Indicates that the pump is being forced on
by the delay function to allow the heater
to cool down
Air_Sensor_OK D
When high/active indicates that the freeze
sensor is functioning properly
Solar_Sensor_OK D
When high/active indicates that the solar
sensor is functioning properly; solar
heating will not be allowed if low/inactive
Water_Sensor_OK D
When high/active indicates that the water
sensor is functioning properly; heating will
not be allowed if low/inactive (ignored on
Model 3820)
Aux3_Is_Dimmer D
When high/active indicates Aux3 is
configured as a dimmer rather than a
standard relay circuit; requires a special
dimmer module; on Model 3820, this
circuit is referred to as Aux5
Aux4_Is_Dimmer D
When high/active indicates Aux4 is
configured as a dimmer rather than a
standard relay circuit; requires a special
dimmer module; on Model 3820, this
circuit is referred to as Aux6
Floor_Cleaner_On
D
When high/active indicates floor cleaner
system is active
Backwash_State D
When high/active indicates that a
programmed Backwash Cycle is taking
place; requires that Aux7 has been
configured and programmed as a
backwash circuit
Freeze_Present D
When high/active indicates at least 1
circuit has been configured to protect the
equipment during a freeze