Operating instructions
Error_5 D
When "high" indicates that an error has
been detected at the spa side remote (like
it has been disabled)
Spa_Heater_On_
(Model_3830)
D
When high/active, indicates that the spa
heater for Model 3830 is on
Spa_Solar_On_
(Model_3830)
D
When high/active, indicates that the spa
solar for Model 3830 is on
Model_3(XXX) D
Real feedback indicating Compool model
that you are communicating with
Pool_Temp_Desired(F) A
Real feedback indicating current desired
control temp of pool water
Solar_Temp(F) A
Current solar temperature in degrees
Fahrenheit
Spa_Temp_Desired(F) A
Real feedback indication current desired
control temp of spa water
Spa_Solar_Temp(F) A
Current spa solar temp in degrees
Fahrenheit (Model 3830 only)
Pool_Temp(F) A Current water temp in degrees Fahrenheit
Spa_Temp(F) A
Current spa water temp in degrees
Fahrenheit (Model 3830 only)
Air_Temp(F) A
Current air temp in degrees Fahrenheit;
used to determine freeze mode conditions
To_Device$ S
Routed to COM port for command strings
sent to Compool
OPS USED FOR TESTING: 3.015
COMPILER USED FOR TESTING: SimplWindows Ver 2.03.12
SAMPLE PROGRAM: Compool CP3800 Demo
REVISION HISTORY: None