User`s guide
8
Compool/EasyTouch Pool and Spa Control System Upgrade Installation and User’s Guide
Compool/EasyTouch Upgrade Outdoor Control Panel Operating Modes
The Compool/EasyTouch system can run in automatic mode or manual mode. Use the “Mode” button to switch
the system from “Auto” mode (normal operating mode) to “Service” for manual operation and service purposes.
Before operating EasyTouch, familiarize yourself with the LCD status messages and operating buttons.
AUTO (Automatic): The system is in normal
operating mode. Scheduled programs will run
automatically.
HEATER: Displays the heat source (Off, Heater,
Solar Prf., Solar) as specified in the Heater menu
settings (see page 25). When the Filter Pump (F)
button is pressed in “Pool” or “Spa” mode, and heat
source is enabled (Heater button LED on).
POOL (SPA): Indicates that the Valves (V) button is
in “Pool” or “Spa” mode and the Filter Pump (F)
button has been pressed to switch on the filter
pump. If this display line is blank, it indicates no
spa or pool function is active. For an EasyTouch
single body system, Hi-Temp (Spa) / Lo-Temp (Pool)
sets the temperature settings (see page 37)
95° F / 100° F: Displays the actual spa or pool
water temperature (95° F) and the set point tem-
perature (100° F) as set in the “Heater” menu.
AIR: Displays the actual outside air temperature
(70° F) as read by the air sensor located near the
EasyTouch Load Center.
Date and Time: Displays the EasyTouch system
day and time as specified in the “Clock” menu
settings (see page 31).
Filter Pump button:
For spa operations, press the Valves (V) button to
rotate valves into “Spa” mode, then press the
Filter (F) button to activate the filter pump. Press
the Valves button to toggle to “Pool” mode. The
Heater button LED will be on if a heat source is
enabled in the Heat menu.
F
VALVES
HEATER SOLAR
FILTER
PUMP
MODE
MODES OF OPERATION
Auto:
Indoor control panel and other remote devices operate system.
Service:
Service buttons on this panel operate system.
Other remote devices are disabled.
Time Out:
Service buttons on this panel operate equipment for
three hours, then settings return to Auto mode.
V
Pool
Spa
Fill (Spillway)
Drain
1
2
3
4
5
6
7
MENU SELECT
Reset
Upgrade
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
AUX 6
AUX 7
AUTO HEATER
SPA 95 F / 100 F
AIR 70 F
MON 09:30 AM
Valves (V) button: When in normal operating mode, the system is in
“Pool” mode so that only the pool water is circulated through the
system. Press the Valves button to enable “Spa” mode and to rotate
valves and activate the Filter pump (Filter Pump LED on)
automatically so that only the spa water is circulated through the
system. Note that the filter pump will switch off while the pool/spa
valves are rotating into position.
“Fill/Spillway” and “Drain” modes are
used only in “Service” mode.