Service manual
P-4
06/2005
   Error Display Mode
If selection button two is pressed at the “ ” prompt, the controller will enter the Error 
Display Mode.  If no errors have occurred, the display will show “ ”. If an error has been 
detected since the last error reset, the display will show the rst error summary code that 
has occurred. If selection button three is pressed while displaying any summary code, the 
controller will return to the “ ” prompt. 
Note: See the Trouble Shooting section for errors and how to clear them.
EXAMPLE: “ ” would indicate a column jam error in column 1.
 Coin Pay Out/Tube Fill Mode
If selection button two is pressed at the “ ” prompt, the controller will enter the Coin 
Pay Out Mode. Pressing selection one will scroll through the denominations and pressing 
selection  button  two  will  start  the  denomination  ashing.  The  display  will  indicate  the 
denomination along with the number of that coin stored in the coin mechanism. If selection 
button two is pressed, a pay out of the displayed value will be made.  Coins will continue to 
pay out as long as that selection button is held down.
EXAMPLE: If selection button two is pressed while 5 cents is displayed it will pay out a 
nickel.
When the controller enters the “ ” mode, the operator is allowed to deposit any coin into 
the coin changer’s acceptor when that coin’s tube is not full.  The tube inventory level will 
be displayed after each coin is accepted.
   Test Mode
If selection button two is pressed at the “ ” prompt, the controller will enter the Test 
Mode where you are able to test the motors, the display, the compressor, the lights, the 
evaporator fans and the heater.
   Vend Testing
Pressing selection button two at the test mode will enter the controller into the vend test 
mode. Upon  entry  into  the  vend  test  mode the  display  will  show  the  rst  summary test,       
 (column 1). Pressing selection button one will scroll through the column selections. 
Pressing selection button two will test vend the displayed column. In order to exit the setting, 
press selection button three.
SET-UP AND CODE DESCRIPTION