Installation guide

2-4
Bull S.A.May 25th, 1999
1.6 DiskArray Warning
The capacity of a disk drive bound as a hot spare must not be lower than the disk it
might replace.
If there are outstanding writes when the SP owner is changed, a background verify
automatically starts.
If an UNDETERMINED ERROR is reported on a SCSI adapter, check that:
the SCSI cabling is correct,
each SCSI bus connector is firmly latched in place,
each SCSI–bus is terminated with the proper differential terminator.
Before upgrading a DAS 2900 flare firmware, you should:
make a backup of your data,
unbind your RAID3 LUN,
upgrade the flare,
bind your RAID3 LUN,
restore your data.
Documentation Erratum: “Using DASSMGR”
(86 A2 56JX)
The designations
Physical Disk Unit
and
Physical Unit
that are displayed in the screens
of the ”
Using DASSMGR to Configure and Manage a DAS”
manual (86 A2 56JX) have
to be replaced respectively by
Logical Disk Unit
and
Logical Unit
.
1.7 ArrayGUIde Warning
At least one Logical Disk Unit must be configured to enable ArrayGUIde to access
DAS. Use dassmgr
and an asynchronous port to create the first Logical Disk Unit.
If you use ATF and ArrayGUIde, you must use sp objects in the ArrayGUIde
configuration file instead of hdisks as devices to access the DAS Subsystem.
ArrayGUIde and dassmgr differently display the disk capacities:
ArrayGUIde displays
available disk capacities,
whereas
dassmgr displays
raw disk
capacities.