User`s guide

The following bytes contain the print quality selection, as shown:
Byte Value Description
Bit 0-1 F800 PQC Order Code
Bit 2 01 - 2A Fast Draft Quality
2B-55 DP
56 - AA DP Text
AB - FE NLQ
FF Depends on Operator Panel setting
Note: Model Z03 only with Host Fast Draft enabled.
For printing multiple-density selections of graphics and bar codes, the following values are valid if bar
code/graphics density is set to computer selected:
Byte Value Description
Bit 0-1 F800 PQC Order Code
Bit 2 01 - 55 Low-Density Graphics/Bar Codes
56 - FE High-Density Graphics/High-Contrast Bar Codes
FF Depends on Operator Panel setting
Notes:
1. A PQC command can result in a font change in order to provide the desired quality level.
2. The printer changes fonts to satisfy quality selections for all supported code pages except OCR (340),
OCR-A (892), or OCR-B (893). It will not change the selected code page to provide a requested
quality.
Text Function Set Commands
The text function set contains the commands and data controls for presenting text information on a logical
page, page segment, or overlay area on the physical medium. The following commands are the text
function set:
Command Code Description
LE D61D Load Equivalence
WT D62D Write Text
The following pages describe the text function set commands.
Load Equivalence (LE)
Length D61D Flag Correlation ID (Optional) DATA
This command permits Begin and End suppression controls imbedded in data stored within the printer to
reference different external values. For example, internal suppression values of 06, 07, and 09 (from a
Begin Suppression control) can map to an external value of 02 from a Load Copy Control command, if the
printer previously has received an appropriate Load Equivalence command. Thus, the printer can use a
single Load Copy Control suppression pair for more than one suppression value (see “Begin Suppression
(BSU)” on page 137).
Chapter 4. IPDS Programming Information 133