Installation manual

28
Option Menu Descriptions
Only uncommon options are described in this section.
1-03 Driver’s Priority Unlock
- The driver’s door must be isolated from the other doors. Use the
Orange/Black CN4 as your 2
nd
Unlock output.
1-04 Double Pulse Unlock
– This feature cannot be used with Option 1-03. This feature provides a
double pulse on the blue unlock wire.
1-05 Rearm Output
– Optional settings to change the event trigger on the orange rearm wire.
1-06 Reservation Lock
– Manual transmission only. Setting III will provide a 10 second delay before
the vehicle shuts off after closing the last door to allow for another door to open. Upon a door
opening, the user will have 2 minutes to close the last door in order for reservation mode to set.
1-09 Ignition Controlled Locks
– Setting 2 will lock the doors when the foot brake is pressed and
doors closed. Tach sensing mode must be used for setting 3. You must also turn this feature on
through the remote by tapping I+IV (2 Way remotes) or Lock+Key (1 Way remotes)
1-10 Auto Relock
– This option will automatically relock/rearm after the system has been disarmed
and the doors have not been opened.
1-11 Ignition / Accessory Upon Unlock
– This option will pulse the ignition wire, accessory, or both
upon unlock/disarm. Most new Chrysler vehicles need the ignition and accessory pulsed to
disarm the factory alarm.
1-14 Auto Lock Mode
– This option must be set for the Auto Mode on 2 Way international remotes to
function.
2-01 Tach Sensing Method
– This option will adjust the method at which tach is read by the module.
At default the current setting will minimize overcrank.
2-02 Turbo Mode
– This option will adjust the run time after Turbo mode has been engaged.
The e-brake and door trigger input must be connected and the feature must be turned on through
the remote for this feature to work.
2-03 Diesel Timer
– Use this option if you can’t find the glow plug wire. You can use setting 2 for a
default wait to start of 10 seconds, otherwise, you can adjust the time with your OP500
Programmer.
2-04 Trigger Start
– This option changes the number of times required for a negative (-) start input on
Pin 12 of CN3.
2-05 Cold Start
– This option turns on the cold/hot starting features. This option works in conjunction
with 2-6, 2-8 and 2-9. The thermistor must be plugged into the controller/brain.
2-06 Timer Start or Interval Between Cold Start
- This option dictates the time interval when the
control module will either remote start or check the temperature and remote start.
Default 1: Will start every 3 hours until the vehicle is remote started or started by key and run for 4 minutes.
Option 2: Will start every 1.5 hours until the vehicle is remote started or started by key and run for 4 minutes.
Option 3: Will start at the time specified on the 2 way remote once within 24 hours and run based on Option 2-07.