Manual Chapter 5

5-32 Using UltraSpec Alignment - General Overview
Tolerance Example
Tolerance Chart (2000 to 3500 RPM)
The chart above shows the Angle and Offset for a machine that operates at
2000 – 3500 RPM plotted together. A pure angle reading of 0.45 Mils/Inch
and a pure Offset reading of 2.5 Mils are marked by the arrows. These read-
ings are clearly in the acceptable range when looked at individually. How-
ever, look what happens when these two “acceptable” reading are plotted
together. The two lines connect outside the acceptable range. This illus-
trates the importance of looking at the Offset and Angle together when
establishing specified tolerances.
Excellent
Acceptable
Offset (mils)
Angle (mils/inch)
12 3
0.25
0.50