Manual Chapter 5

6-17
After the job has been defined and any soft foot condition corrected (if nec-
essary), select Alignment Data to acquire a new set of shaft readings.
The current laser readings are shown in reverse video just below the title
line of the data acquisition screen. When the laser heads are at one of the
desired clock positions, the angle readouts at the bottom center of the
screen get cross hatches over the numbers, you will hear the analyzer beep
(and the red LED on the front panel of the analyzer will illuminate) each
time a new reading is measured. The heads must be within one degree of
the desired position (average of both angles). In Auto mode the data is auto-
matically placed in the correct clock position and it is averaged continu-
ously until you move out of the desired clock position. You can clear and
restart the averager at any time by pressing the Alt/Delete key while read-
ings are being acquired. The data at the four clock positions is the averaged
value. The position currently highlighted is the one for which data is being
acquired.
If the laser heads can only be rotated to three of the positions, then press
Enter after the third set of data has been collected, and the fourth is auto-
matically calculated. Using only three readings increases the likelihood of
error and does not allow the instrument to check data validity. CSI does not
recommend using only three readings if four are available.
11