User's Manual
Table Of Contents
- Home
- Contents
- CSI 2140 Machinery Health Analyzer
- Introduction to the analyzer
- Transfer files with CSI 2140
- AMS Machinery Manager Data Transfer
- AMS Machinery Manager Standalone Data Transfer application
- Communication setup
- Routes and jobs
- Load a route from AMS Machinery Manager into the analyzer
- Load multiple routes from AMS Machinery Manager to the analyzer
- Load a Balance job from AMS Machinery Manager into the analyzer
- Dump a job from the analyzer to AMS Machinery Manager
- Dump a route from the analyzer to AMS Machinery Manager
- Dump a route or job from the analyzer to a folder on a computer
- Analyzer firmware and programs
- Screen captures
- Splash screens
- Printing
- Route
- Route overview
- Manage routes
- Set data collection and display parameters
- Set the plot type for collected data
- Enable or disable Point Advance to automatically move to the next measurement point
- Set High Frequency Detection averages
- Set the route data storage mode
- Set the overlap
- Set the plot type for live data
- Set the overall mode
- Set the integrate mode
- Enable or disable multi-channel group data collection
- Display a summary of data collected for grouped measurement points
- View or hide warning alarms on the Route Data Collection screen
- Restore default values for route data collection and display parameters
- Override the sensor setup for a route
- Enter new speed or load for a measurement point
- Tachometers
- Multiple inputs and measurements
- Collect route data
- Notes
- Plot data
- Run Analyze to collect data for a route measurement point
- View the measurement point setup and history
- Route reports
- Plots
- Analyze and Advanced Analyze
- Analyze overview
- Manage jobs
- Job Setup
- View all saved Analyze jobs
- Create an Analyze job
- Open a saved Analyze job
- Change the job ID
- Edit the equipment ID and description in a job
- Edit the measurement ID and description in a job
- Add a measurement
- Delete a measurement
- Delete data from the current measurement point
- Save a job to equipment in a route
- Set display parameters
- Multi-input measurements
- Sensors and inputs
- Tachometers
- Common data collection parameters
- Collecting data using an Analysis Expert
- Recommended uses of Analysis Experts
- Enable or disable the help text in the Analysis Experts
- High Frequency Analysis
- High Resolution Analysis
- Bearing/Gear Analysis - PeakVue
- Low Frequency Analysis - Slow Speed Technology
- Turning Speed Detection
- Laser Speed Detection
- Bump Tests
- Bump Test Equipment Off
- Bump Test Equipment Running
- Coast Down Peak Hold
- Coast Down Peak and Phase
- Rotor Bar Test Motor Current
- Order Tracking
- Synchronous Analysis
- Synchronous Analysis and Synchronous Averaging
- Orbit Plot
- Cross Channel Amplitude/Phase
- Collect data using Manual Analyze
- Listen to live vibration data in Analyze
- Redo a measurement
- Store data to a route or a job
- Review collected data
- Print an Analyze plot to AMS Machinery Manager
- Print a plot to a memory card
- Reset Analyze defaults
- Advanced Transient
- ODS/Modal
- ODS/Modal overview
- Manage jobs
- Sensors and inputs
- Tachometers
- Set up the plots
- Set up the job
- Collect ODS/Modal data
- Display the data for a measurement point
- Print an ODS/Modal plot to AMS Machinery Manager
- Print an ODS/Modal plot to a memory card
- Balance
- Balance overview
- Manage jobs
- Job Setup
- Sensor Setup
- Measurement Plane Setup
- Weight Plane Setup
- Acquire Data
- Balance correction
- Trim run
- One-run balance job
- Notes
- Balance summary reports
- Review balance data
- Manually enter balance job data
- Calculator Mode
- Determine another location to place weights
- Combine multiple weights on a rotor
- Calculate a new balance solution to use only the available weights
- Calculate weight placement using static and couple components
- Estimate trial weights
- Calculate weight location around the outside rotor circumference
- Calculate new balance solution to use only available locations and weights
- Amplification Factor
- Convert magnitude or frequency values to a different measurement unit
- Tips and additional information
- Balance accessories
- Technical specifications
- Glossary
- Index
![](/manual/computational-systems/csi2140m1/user-s-manual-english/images/img-4.png)
5.1 View a full screen version of the plot .............................................................................................81
5.2 Select an active plot ...................................................................................................................... 81
5.3 Switch the plot type ...................................................................................................................... 82
5.4 Add or remove a cursor ................................................................................................................. 82
5.5 Change the cursor type ................................................................................................................. 83
5.6 Change the scale of the x and y axis ...............................................................................................83
5.7 Expand or compress the X axis ...................................................................................................... 84
5.8 View the highest frequency peaks on the spectrum plot ............................................................... 84
5.9 Set RPM ........................................................................................................................................ 84
5.10 View fault frequencies ...................................................................................................................85
Chapter 6 Analyze and Advanced Analyze ....................................................................................... 87
6.1 Analyze overview .......................................................................................................................... 87
6.2 Manage jobs ................................................................................................................................. 91
6.3 Set display parameters ..................................................................................................................94
6.4 Multi-input measurements ........................................................................................................... 95
6.5 Sensors and inputs ........................................................................................................................ 95
6.6 Tachometers .................................................................................................................................97
6.7 Common data collection parameters ............................................................................................99
6.8 Collecting data using an Analysis Expert ......................................................................................105
6.9 Collect data using Manual Analyze .............................................................................................. 119
6.10 Listen to live vibration data in Analyze .........................................................................................138
6.11 Redo a measurement ..................................................................................................................140
6.12 Store data to a route or a job .......................................................................................................140
6.13 Review collected data ................................................................................................................. 141
6.14 Print an Analyze plot to AMS Machinery Manager ........................................................................141
6.15 Print a plot to a memory card ...................................................................................................... 141
6.16 Reset Analyze defaults ................................................................................................................ 142
Chapter 7 Advanced Transient ...................................................................................................... 143
7.1 Advanced Transient overview ..................................................................................................... 143
7.2 Manage jobs ............................................................................................................................... 147
7.3 Sensors and inputs ...................................................................................................................... 149
7.4 Tachometers ...............................................................................................................................151
7.5 Select a section of the full transient waveform ............................................................................153
7.6 Set the number and type of plots to display ................................................................................ 155
7.7 Set data collection parameters ....................................................................................................155
7.8 Collect transient data ..................................................................................................................157
7.9 Plot data ..................................................................................................................................... 158
Chapter 8 ODS/Modal ................................................................................................................... 161
8.1 ODS/Modal overview ..................................................................................................................161
8.2 Manage jobs ............................................................................................................................... 165
8.3 Sensors and inputs ...................................................................................................................... 168
8.4 Tachometers ...............................................................................................................................170
8.5 Set up the plots ...........................................................................................................................172
8.6 Set up the job ..............................................................................................................................173
8.7 Collect ODS/Modal data ..............................................................................................................177
8.8 Display the data for a measurement point ...................................................................................180
8.9 Print an ODS/Modal plot to AMS Machinery Manager ..................................................................180
8.10 Print an ODS/Modal plot to a memory card ................................................................................. 181
Chapter 9 Balance ......................................................................................................................... 183
9.1 Balance overview ........................................................................................................................ 183
Contents
ii
DRAFT