User's Manual
Table Of Contents
- Home
- Contents
- CSI 2140 Machinery Health Analyzer
- Introduction to the analyzer
- Transfer files with CSI 2140
- AMS Machinery Manager Data Transfer
- AMS Machinery Manager Standalone Data Transfer application
- Communication setup
- Routes and jobs
- Load a route from AMS Machinery Manager into the analyzer
- Load multiple routes from AMS Machinery Manager to the analyzer
- Load a Balance job from AMS Machinery Manager into the analyzer
- Dump a job from the analyzer to AMS Machinery Manager
- Dump a route from the analyzer to AMS Machinery Manager
- Dump a route or job from the analyzer to a folder on a computer
- Analyzer firmware and programs
- Screen captures
- Splash screens
- Printing
- Route
- Route overview
- Manage routes
- Set data collection and display parameters
- Set the plot type for collected data
- Enable or disable Point Advance to automatically move to the next measurement point
- Set High Frequency Detection averages
- Set the route data storage mode
- Set the overlap
- Set the plot type for live data
- Set the overall mode
- Set the integrate mode
- Enable or disable multi-channel group data collection
- Display a summary of data collected for grouped measurement points
- View or hide warning alarms on the Route Data Collection screen
- Restore default values for route data collection and display parameters
- Override the sensor setup for a route
- Enter new speed or load for a measurement point
- Tachometers
- Multiple inputs and measurements
- Collect route data
- Notes
- Plot data
- Run Analyze to collect data for a route measurement point
- View the measurement point setup and history
- Route reports
- Plots
- Analyze and Advanced Analyze
- Analyze overview
- Manage jobs
- Job Setup
- View all saved Analyze jobs
- Create an Analyze job
- Open a saved Analyze job
- Change the job ID
- Edit the equipment ID and description in a job
- Edit the measurement ID and description in a job
- Add a measurement
- Delete a measurement
- Delete data from the current measurement point
- Save a job to equipment in a route
- Set display parameters
- Multi-input measurements
- Sensors and inputs
- Tachometers
- Common data collection parameters
- Collecting data using an Analysis Expert
- Recommended uses of Analysis Experts
- Enable or disable the help text in the Analysis Experts
- High Frequency Analysis
- High Resolution Analysis
- Bearing/Gear Analysis - PeakVue
- Low Frequency Analysis - Slow Speed Technology
- Turning Speed Detection
- Laser Speed Detection
- Bump Tests
- Bump Test Equipment Off
- Bump Test Equipment Running
- Coast Down Peak Hold
- Coast Down Peak and Phase
- Rotor Bar Test Motor Current
- Order Tracking
- Synchronous Analysis
- Synchronous Analysis and Synchronous Averaging
- Orbit Plot
- Cross Channel Amplitude/Phase
- Collect data using Manual Analyze
- Listen to live vibration data in Analyze
- Redo a measurement
- Store data to a route or a job
- Review collected data
- Print an Analyze plot to AMS Machinery Manager
- Print a plot to a memory card
- Reset Analyze defaults
- Advanced Transient
- ODS/Modal
- ODS/Modal overview
- Manage jobs
- Sensors and inputs
- Tachometers
- Set up the plots
- Set up the job
- Collect ODS/Modal data
- Display the data for a measurement point
- Print an ODS/Modal plot to AMS Machinery Manager
- Print an ODS/Modal plot to a memory card
- Balance
- Balance overview
- Manage jobs
- Job Setup
- Sensor Setup
- Measurement Plane Setup
- Weight Plane Setup
- Acquire Data
- Balance correction
- Trim run
- One-run balance job
- Notes
- Balance summary reports
- Review balance data
- Manually enter balance job data
- Calculator Mode
- Determine another location to place weights
- Combine multiple weights on a rotor
- Calculate a new balance solution to use only the available weights
- Calculate weight placement using static and couple components
- Estimate trial weights
- Calculate weight location around the outside rotor circumference
- Calculate new balance solution to use only available locations and weights
- Amplification Factor
- Convert magnitude or frequency values to a different measurement unit
- Tips and additional information
- Balance accessories
- Technical specifications
- Glossary
- Index
![](/manual/computational-systems/csi2140m1/user-s-manual-english/images/img-8.png)
CAUTION!
A caution paragraph alerts you to actions that may have a major impact on the equipment or
stored data.
WARNING!
A warning paragraph alerts you to actions that may have extremely serious consequences for
equipment and/or personnel.
1.4 General maintenance and precautions
Any maintenance, repair, or replacement of components not listed below must be
performed by specially trained personnel at Emerson authorized service centers. Any
damage to the product caused by misuse, abuse, neglect, carelessness or modifications
performed by anyone other than Emerson may void the warranty.
Following the precautions listed below, you can perform common maintenance
procedures on the CSI 2140 and its accessories.
WARNING!
• An electrostatic discharge is possible when you clean the equipment exterior. When
cleaning the equipment exterior, do not use any abrasive or corrosive chemicals or
materials. Do not use petroleum distillates and ketone solvents, for example, acetone,
gasoline and kerosene. Use a dry, lint-free towel or cloth dampened with a mild soap
and water solution. Clean the analyzer only in a non-hazardous area.
• Charge, remove, and replace the battery pack only in a non-hazardous area.
• Use only Emerson's battery packs with the CSI 2140. Lithium-Ion batteries have very
specific charging requirements. Emerson-supplied power supplies and chargers are
designed to work with Emerson's Lithium-Ion battery pack. Using battery packs other
than Emerson's approved battery packs could not only void the warranty, but could also
be hazardous.
Precautions
• To prevent permanent damage to the touchscreen on the CSI 2140, never use sharp
objects or excessive pressure with your fingers or stylus. Lightly tap the screen.
• Use only Emerson's power supplies and chargers approved for use with the CSI 2140
and Emerson's battery packs. Using any power supplies and chargers other than
Emerson's approved power supplies and battery packs could not only void the
warranty, but will also most likely damage the analyzer or the battery pack.
• Do not change or remove the battery pack in the CSI 2140 with the power supply
connected to the analyzer. The CSI 2140 or battery pack may be damaged.
• Do not use Emerson's battery packs, power supplies, and chargers with any product
other than their corresponding Emerson product.
CSI 2140 Machinery Health Analyzer
2
DRAFT