User's Manual

Table Of Contents
84
BTTracer Protocol Analyzer Users ManualCATC Version 1.0
The Actions window showing a condition based on a Poll packet and a
counter. This condition reads "Trigger after the 21st Poll packet."
Connecting Events to Counters
To connect an event to a counter, click an Event button, then click one of the
two counter buttons. An arrow will appear that will join the Event to the
Counter and then to a trigger.
This latter connection between the Counter button and the Trigger button
occurs because counters always work in association with triggers. Counters
act as assistants to triggers.
Setting Multiple Conditions with Counters
You can create multiple event conditions by linking a counter to multiple
events or by linking two counters to two or more events.
Linking Multiple Events to One Counter - When two or more Events are
connected to a counter, it creates a condition that reads "Trigger when the
counter value is reached by any combination of the specified events."