Installation manual
MNC-0500-002 24 of 36 Revision H
Amplifier Communication and Protocol, Octagon ISA CPU
‘P’ Fwd Power
XX.X in dBm HV OFF or RF not detectable
“<XX”
‘Q’ Reverse Power
XX.X in dBm HV OFF or RF not detectable
“<XX”
‘R’
Reverse Power Alarm/Fault
trip point and setting
A XX.X in dBm (generate alarm)
F XX.X in dBm (generate fault)
D XX.X in dBm (disabled)
‘r’
Reverse Power Alarm/Fault
Trip point and setting
XXXX in Watts
‘T’ TWT Temp
XXXX in
o
Celsius (Right Justified and Padded
with Spaces.)
‘V’ Helix Voltage XX.X in KV
‘Z’ Linearizer Amplitude
0 → 4095 counts
conversion equation is V=Z*(10/4096)
‘z’ Linearizer Phase
0 → 4095 counts
conversion equation is V=z*(10/4096)
Compatibility: The XTC-100D supports the following parameter subset (when querying it
for amplifier status): ‘1’, ‘3’, ‘8’, ‘I’, ‘M’, ‘N’, ‘P’, ‘Q’, ‘T’, and ‘V’. Note that Parameters ‘M’ and
“N” are only available for digital HPAs. Redundant Controllers turn around ‘1’, ‘8’, ‘I’, ‘P’, ‘Q’,
‘T’, ‘V’. Dual Path Controllers pass through queries regardless of parameters. Parameters
‘Z’ and ‘z’ are only available with HPAs that have the linearizer option.