Installation manual

MNC-0500-002 31 of 36 Revision H
Amplifier Communication and Protocol, Octagon ISA CPU
Miscellaneous Setup
Command Byte: 'P'
Function: Miscellaneous Setup
Parameters: “ZXXXX” to set linearizer amplitude, “zXXXX” to set linearizer phase.
XXXX is a count between 0 and 4095.
Note: You can convert counts to volts using the conversion equation V=counts*10/4096.
Compatibility: Linearizer required
Parameters: “CX” ti set Configuration Mode.
X is the redundancy mode you wish to operate.
0 — is single thread no waveguide switch.
1 — is redundant system with one waveguide switch (1:1 configuration).
2 — is power combined system with two waveguide switches (1+1 configuration).
3 — is redundant system with a load switch on the output (1:1 w/load).
4 — Reserved.
Enable RF Limits
Command Byte: 'R'
Function: Enables RF Limit Checking
Note: This command is obsolete as of firmware version 3.73. (Use commands 'L': Low
RF Trip, 'M': High RF Trip, and ‘O’: Reflected Power).
Disable RF Limits
Command Byte: 'S'
Function: Disables RF Limit Checking
Note: This command is obsolete as of firmware version 3.73. (Use commands 'L': Low
RF Trip, 'M': High RF Trip, and ‘O’: Reflected Power).
Set Frequency
Command Byte: 'T'
Function: Tells unit what frequency it is running at.
Response: “TXX.XX”
XX.XX is the frequency in GHz
Notes: Affects reported power in outdoor controllers (XTC-100D) only.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.