XTRD-400K, 400W, SNG
Document No. 305-0062-301 REV C Page 3 of 10
3.1.10 Noise Power
3.1.10.1 Transmit Band (13.75-14. 5 GHz) -70 dBw/4KHz max
3.1.10.2 Receive Band (10.95-12.75 GHz) -150 dBw/4KHz max
3.1.11 Group Delay, any 80 MHz
3.1.11.1 Linear 0.01 nS/MHz max
3.1.11.2 Parabolic 0.005 nS/MHz squared max
3.1.11.3 Ripple 0.5 nS/Pk-Pk max
3.1.12 Residual AM Noise -50 dBc up to 10 KHz max
-20(1.5+Log(Freq)) dBc fm 10 to 500 KHz max
-85 dBc above 500 KHz max
3.1.13 Phase Noise profile 10 dB below IESS phase noise
3.1.14 Spurious Signals
3.1.14.1 Spurious Signals, spectral limits -37 dBc up to 10 KHz max
-20(1.5 + log(f))+13 10 to 500 KHz max
-72 above 500 KHz max
3.1.14.2 Line Related, individual -50 dBc
3.1.14.3 Power Line Related, sum of all -47 dBc
3.1.15 VSWR
3.1.15.1 Input 1.3:1 max
3.1.15.2 Output 1.3:1 max
3.1.16 Prime Power 100-260 VAC
1400 VA max
0.95 Power factor min
45 to 63 Hertz
Single Phase
3.1.17 Serial Interface
3.1.17.1 RS-232 COM1
3.1.17.2 RS-422/485 (4-Wire Mode or COM2
2-Wire Mode)
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.