Installation manual
Unpacking and Installation
MNC-0300-001 11 of 20 Revision L
Note 1: Pins 3,4,5 — Form C contacts. Fault 1, Summary Fault.
Note 2: Pins 6,7,8 — Form C contacts. Fault 2, Summary Fault
(Used for redundant systems).
Summary Fault Indicators
Two sets of Form C relay contacts (Summary Fault 1 and
Summary Fault 2) are used to indicate that a fault has occurred.
The Summary Fault 1 indicator signals change state any time an
amplifier fault occurs. The user has the choice of a normally
open or normally closed circuit.
Table 1, Auxiliary Connector Pinouts
Pin Nr. Definition Comments
1 +24 VDC Available for external use.
2 +24 VDC Current limit of 100mA.
3 (Note
1)
Summary Fault 1 Normally Open. Closes when fault occurs.
4 Summary Fault 1 Normally Closed. Opens when fault occurs.
5 Summary Fault 1 Common, Fault 1
6 (Note
2)
Summary Fault 2 Common, Fault 2
7 Summary Fault 2 Normally Open. Closes when fault occurs.
8 Summary Fault 2 Normally Closed. Opens when fault occurs.
9 Ground
10 Ground
11 External Interlock
Return
Pin 11 must be connected to Pin 13 to enable
High Voltage ON.
12 RF Inhibit Connect Pin 12 to Pin 9 or Pin 10 to inhibit RF
Output.
13 External Interlock Pin 13 must be connected to Pin 11 to enable
High Voltage ON
14 +15 VDC Monitor Only
15 -15 VDC Monitor Only.