The Summary Fault 2 indicator signals change state any time a
summary fault occurs. The user has the choice of a normally
open or normally closed circuit.
Output Voltage
A + 24 VDC voltage is supplied that can deliver up to 100 mA.
This supply voltage is available on both Pins 1 and 2. The return
for this voltage is either Pin 9 or Pin 10.
Power and Interface Interconnections
When performing the procedures in this section refer to the
Wiring and Interconnect Drawings for your specific amplifier.
These drawings are located in the appendix titled Interconnect
Drawings.
Prime Power Connections
Single Phase Units
The AC Prime Power receptacle is located on the amplifier rear
panel. See the appendix titled Specification for nominal line
voltage and prime power connects. Figure 4 shows the plug
wiring diagram.
Title
Figure 4, Power Plug Wiring Diagram
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject