Product specifications

Ku-Band Solid-State Power Amplifier Revision 1
Introduction MN/KPA.IOM
1–8
1.3.4 KPA-100 Specifications
Parameters Specifications
Input
Level -10 dBm Typical
Impedance
50Ω
Noise Figure 10 dB typical, 15 dB maximum @ max gain
VSWR 1.25:1 Maximum
Connector SMA Female
Output
Frequency 14.0 to 14.5 GHz
Power 49.5 dBm min @ 1 dB Compression
Mute -60 dB
Impedance
50 Ω
VSWR 1.25:1 Maximum
Connector WR75G Waveguide
Gain
Linear 65 dB minimum, 70 dB typical
Adjust 20 dB in 0.25 dB steps
Fill Band
± 0.75 dB
Per 40 MHz
± 0.25 dB
0 to +50°C (32 to 122°F) ± 0.50 dB @ center frequency
± 1.00 dB full band
Third Order Modulation
Products -30 dBc typical @ –25 dBc maximum @ 3 dB
total backoff (2 tones, Δf = 1 MHz)
AM to PM Conversion
Output 2.0 degrees typical, 3.0 maximum @ rated output
Group Delay (per 40
MHz)
Linear
± 0.03 ns/MHz
Parabolic
± 0.003 ns/MHz
2
Ripple 1.0 ns Peak-to-Peak
Front Panel
Display 24 x 2 LCD
Data Entry Cursor Control Keypad (6 keys)
Output Sample
Type N female, 50
Ω
, –40 dBc
Input Sample
Type N female, 50
Ω
, –20 dBc
Remote Control
COM Port
EIA-232 or EIA-485
Protocol
ASCII
Alarms
Summary Fault Form C
LEDs
Power On Green
Fault Red
Stored Fault Red
TX On Yellow
Online Yellow
Remote Yellow
Mechanical
Envelope 8.75H x 19W x 24D inches
(22.22H x 48.26W x 60.96D cm)
Weight 75 lbs (34 kg)
Environmental
Temperature Operating
0 to 50°C (32 to 122°F)
Storage
–40 to 70°C (–40 to 158°F)
Humidity Operating
10 to 95% Noncondensing
Storage 0 to 100% Noncondensing
Altitude Operating
15, 000 ft MSL
Storage 50, 000 ft
Shock Normal Commercial Shipping and Handling
Power Requirements
VAC
180 to 270 VAC, 47 to 63 Hz
1100W nominal