Product specifications

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1
Flash Upgrading MN/KPA.IOM
4–4
10
Verify the file transfer.
a) The M&C PC should report that the file transfer has occurred, and the display on the
KPA will report:
Programming APP flash…
Please wait…
b) The process sequences through several blocks – this will take several minutes. When
it has finished, the KPA front panel will display:
KPA-080-4045-I
Ver. X.X.X SNXXXXXXXXX
c) Terminate the FTP session by typing "bye" and closing the Command-line window.
d) Recycle the power and wait for the unit to reboot.
e) Verify that the new file loaded using the procedure in Step 1.
The Ethernet FTP Upload Procedure is now complete.