Product specifications

KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1
Front Panel Operation MN/KPA.IOM
5–16
5.3.3.1 UTILITY: Date/Time
Edit Real-Time Clock:
12:00:00 24/09/10( ►▲▼E)
Edit the time and date settings of the real-time clock by selecting the digit to be edited using
the arrow keys, then changing the value of the digit using the arrow keys. Press
ENTER when done.
IMPORTANT
Note that in accordance with
European convention, the date is shown in
DAY
-MONTH-YEAR format.
5.3.3.2 UTILITY: CID (Circuit ID)
Edit Circuit ID:( , )
24 CHARACTER TST MESSAGE
Edit the Circuit ID string by using the and arrow keys. Only the bottom line is
available (24 characters). Set the cursor position on the bottom line using the arrow keys,
then edit the character using the keys. The following characters are available:
[Space] ( ) * + -, . / 0-9 and A-Z.
Once the Circuit ID string is composed, press ENTER.
5.3.3.3 UTILITY: PowerMon
Forward Power Mon Offset
Reverse Power Mon Offset
This function allows the user to calibrate (fine tune) the RF Power Monitor for a specific carrier
frequency. The RF Power Monitor is factory-calibrated at the KPA center frequency. The user
can adjust (offset) the display level using this function.
Select Forward Power Mon Offset or Reverse Power Mon Offset using the arrow keys,
then, press ENTER.
If Forward Power Mon Offset is selected:
Forward RF Power Monitor
Offset = +5.8 dBm
Set the cursor position on the bottom line using the arrow keys, then edit the numeric
value using the keys. The range is within -6.0 to +6.0 dBm, in 0.1 dBm steps.
If Reverse Power Mon Offset is selected:
Reverse RF Power Monitor
Offset = -5.8 dBm
Set the cursor position on the bottom line using the arrow keys, then edit the numeric
value using the keys. The range is within -6.0 to +6.0 dBm, in 0.1 dBm steps.