Product specifications

Ku-Band Satellite Transceiver Revision 9
FSK Remote Control Commands MN/KST2000AB.IOM
E-22
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(note that all arguments are ASCII numeric codes, that is,
ASCII codes between 48 and 57)
Response to Command (target to controller) Query
(Instruction
Code and
qualifier)
HPA Stored
Faults (8 Watt)
n.a. 7 bytes Query only.
<add/HSF?X’cr’
>add/HSF=ABCDEFG’cr’’lf’ or
>add/HSF=NO_FAULT’cr’’lf’
Where: A=Overtemperature Status, 0=OK, 1=FLT
B=9.75V Status, 0=OK, 1=FLT
C=-5V Status, 0=OK, 1=FLT
D=BV1 Summary Status, 0=OK, 1=FLT
E=BV2 Summary Status, 0=OK, 1=FLT
F=BV3 Summary Status,. 0=OK, 1=FLT
G=Interprocessor comm. Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)
HSF= (message ok)
HSF? (received ok, but invalid arguments
found)
HSF* (message ok, but not permitted in current
mode)
HSF?
HPA Stored
Faults (25 Watt)
n.a. 13 bytes Query only.
<add/HSF?X’cr’
>add/HSF=ABCDEFGHIJKLM’cr’’lf’ or
>add/HSF=NO_FAULT’cr’’lf’
Where: A=Overtemperature Status, 0=OK, 1=FLT
B=9.75V Status, 0=OK, 1=FLT
C=-5V Status, 0=OK, 1=FLT
D=BV1 Summary Status, 0=OK, 1=FLT
E=BV2 Summary Status, 0=OK, 1=FLT
F=BV3 Summary Status, 0=OK, 1=FLT
G=BV4 Summary Status, 0=OK, 1=FLT
H=BV5 Summary Status, 0=OK, 1=FLT
I=BV6 Summary Status, 0=OK, 1=FLT
J=BV7 Summary Status, 0=OK, 1=FLT
K=BV8 Summary Status, 0=OK, 1=FLT
L=BV9 Summary Status, 0=OK, 1=FLT
M=Interprocessor Comm. Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)
HSF= (message ok)
HSF? (received ok, but invalid arguments
found)
HSF* (message ok, but not permitted in current
mode)
HSF?