Product specifications

MBT-4000 Multi-Band Transceiver System Revision 4
External Connectors MN/MBT4000.IOM
3–8
3.2.1.10 IF OUT (J4, BDC-4000 ONLY)
The J4 IF OUT connector, located on the BDC-4000 Block Down Converter
Module, is a Type ā€˜N’ female connector, used to provide the downcoverted IF
Output signal.
3.2.2 RF Signal Side Connectors
3.2.2.1 REDUNDANT LOOP (J7)
The J7 REDUNDANT LOOP connector is used to connect the MBT-4000 Base
Module, via the Redundant Loop Bus Cable (CEFD P/N CA/WR11224), to
another base unit for a dual base (redundant) setup.
Table 3-8. REDUNDANT LOOP (J7) Connector Pinouts
Pin Signal
A SW POS 2 DRIVE OUT
B GND
C SW POS 2 DRIVE OUT
D RF SW IND OUT
E IF SW IND OUT
F SW POS 1 DRIVE IN
G SW POS 2 DRIVE IN
H RF SW IND IN
J IF SW IND IN
K MBT A IND
L MBT B IND
M NC
N BXC 1 FLT OUT
P BXC 2 FLT OUT
R BXC 1 FLT IN
S BXC 2 FLT IN
T NC
U TX
V RX