Product specifications
MBT-4000 Multi-Band Transceiver System Revision 4
Remote Control MN/MBT4000.IOM
A–10
Parameter
Type
Command
(Instruction
Code and
qualifier)
V
alid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Calibrate LNA
Current
CLC= BDC none Command only.
This command is used to set the calibration point for the LNA
current alarm feature.
Example: CLC=
CLC=(message ok)
CLC?(received ok,
but invalid arguments
found)
CLC*(message ok,
but not permitted in
current mode)
CLC!(command not
accepted by BDC
sub-units.)
N/A N/A
Calibrate LNA
Current
CLC=s MBT
S=1 byte
Value of
1 , 2
1=LNA A
2= LNA 2
Command only.
This command is used to set the calibration point for the LNA
current alarm feature, where s = Source:
1=LNA A (AUX COMM1)
2=LNA B(AUX COMM2)
Example: CLC=1
CLC=(message ok)
CLC?(received ok,
but invalid arguments
found)
CLC*(message ok,
but not permitted in
current mode)
CLC!(command not
accepted by BUC or
BDC sub-units.)
N/A N/A