Product specifications
MBT-4000 Multi-Band Transceiver System Revision 4
Remote Control MN/MBT4000.IOM
A–18
Parameter
Type
Command
(Instruction
Code and
qualifier)
V
alid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Configuration
Status
N/A All 65 bytes
(MBT-4000)
98 bytes
(BDC),
76 bytes
(BUC)
alphanumeric
Query only.
Used to Query the configuration status of the unit
Example for MBT-4000 base:
<0001/RCS?{cr}
>0001/RCS={cr}
BF1=X {cr}
BF2=X {cr}
BT1=DN{cr}
BT2=UP{cr}
RED=0{cr}
RAM=00{cr}
MBT=N, A, or B
EXT=0{cr}{lf}
Example for BDC or BUC:
<0001A1/RCS?{cr}
>0001A1/RCS={cr}
FLO=06300{cr}
ATT=01.00{cr}
MUT=1{cr}
SLP=0.3{cr}
LCS=0{cr}
LCW=99{cr}
LFL=1{cr}
REF=XXXX{cr} (reserved for future use)
XRE=X{cr} (reserved for future use)
AFR=0{cr}{lf}
Note: For BUC, LCS, LCW, & LFL will not be shown.
N/A RCS?
RCS=x….x
(see description
for details of
arguments)
Redundancy
State
RED=x MBT 1 byte,
value of 0,1,
or 2
Command or Query.
Controls redundancy state, where:
0=Off
1=Enables redundancy using single base unit
2=Enables redundancy using dual base units
Example: RED=1
RED= (message OK)
RED? (received OK,
but invalid arguments
found)
RED* (message OK,
but not permitted in
current mode)
RED? RED=x
(same format as
command
arguments)