Product specifications
MBT-4000 Multi-Band Transceiver System Revision 4
Remote Control MN/MBT4000.IOM
A–20
Parameter
Type
Command
(Instruction
Code and
qualifier)
V
alid on
MBT,
BDC, or
BUC
Arguments
for Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Retrieve
Maintenance
Status
N/A All MBT-4000 -
103 bytes,
alphanumeric
BDC –
98 bytes,
alphanumeric
BUC –
98 bytes,
alphanumeric
Query only.
Used to Query the maintenance status of the unit.
Example for MBT-4000 base:
<0001/RMS?{cr}
>0001/RMS={cr}{lf}
15VT1=015.1{cr}
7V5T1=007.7{cr}
5VLT1=005.0{cr}
28VT1=027.2{cr}
REFVT=001.3{cr}
LNA_1=000.0{cr}
LNA_2=000.0{cr}
RFSWP=B{cr}
IFSWP=N{cr}
RRFSW=B{cr}
RIFSW=B{cr}{lf}
Example for BUC:
<0001A2/RMS={cr}
>0001A2/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
POUT=XXX.X{cr} (reserved for future use)
TEMP=+25.0{cr}{lf}
Example for BDC:
<0001A1/RMS={cr}
>0001A1/RMS={cr}{lf}
15VT=015.1{cr}
7V5T=007.6{cr}
5VLT=005.2{cr}
REFV=XXX.X{cr} (reserved for future use)
SYNT=007.2{cr}
LNAC=255.0{cr}
TEMP=+25.0{cr}{lf}
Note: “REFV” will show tuning voltage of reference OSC for
standalone. Otherwise REFV=xxx.x which means Not
Applicable.
N/A RMS?
RMS=x….x
(see description
for details of
arguments)