Product specifications

MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–8
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Automatic Fault
Recovery State
AFR=x
All
1 byte
Command or Query.
Sets or returns Automatic Fault Recovery on a BUC in the form x, where:
x=0 (Disabled) or 1 (Enabled)
Example: AFR=1
AFR=
AFR?
AFR*
AFR?
AFR=x
(same format as
command
arguments)
Attenuation
ATT=xx.xx
BUC
5 bytes,
numeric
Command or Query.
Sets or returns a valid attenuation level, in dB, at 0.25dB step size as
factory default.
Example: ATT=08.25
ATT=
ATT?
ATT*
ATT!
Clear All Stored
Alarms
CAA=
All
None
Command only.
Instructs the slave to clear all Stored Events.
This command takes no arguments.
CAA=
N/A
N/A
Concise AUX
COMM I/O
N/A
MBT
5 bytes, numeric
Query only.
Returns the Concise AUX COMM I/O of the MBT-4000B base unit, in the
form nabcd where:
n=1 (AUX COMM)
a=12V (0=Off, 1=On)
b=IOA (O=logic low [voltage input < 0.5],
1=logic high [voltage input > 2.7 vdc)
c=IOB (O=logic low [voltage input < 0.5],
1=logic high [voltage input >2.7 vdc]
d=Reserved (Always zero)
Example: <0001/CAI?n{cr}
>0001?CAI=nabcd{cr}{lf}
CAI=
CAI?
CAI*
CAI?n
CAI=nabcd
(see Description of
Arguments for
details)