Product specifications

MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–9
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Concise Alarm
Status
N/A
All
20 bytes,
numeric
Query only.
Returns the alarm status of the unit in the form abcdefghijkl where:
a through l=0 (OK) or 1 (FLT)
All:
a=+15V Power Supply
b=+7.5V Power Supply
c=+5.0V Power Supply
MBT-4000B:
d=+28V Power Supply
e=Ref Oscillator Lock Detect
f=Intermodule Communications
g=Max current on LNA power supply AUX COMM
h=Max current on LNB power supply Bias Tee
i=Current window LNA power supply AUX COMM
j=Current window LNB power supply Bias Tee
k=Fault input AUX COMM (Conn J9, Pin F)
l=Not used
BUC/BDC:
d=X (reserved for future use)
e=Synthesizer Lock Detect
f=Heat-sink Temperature
g= LNA current (BDC only, reserved on BUC)
h=Reserved, always zero
i-l=Not sent.
Example: <0001/CAS?{cr}
>0001/CAS=abcdefghijkl{cr}{lf}
N/A
CAS?
CAS=x…X
(see Description of
Arguments for
details)
Circuit
Identification
CID=
All
24 bytes,
alphanumeric
Command or Query.
Sets or returns name for the unit or station. First line is limited to 24
characters.
Example: CID={cr}
-Earth Station 1--
---Converter #1---
CID=
CID?
CID?
CID=x…x
(see Description of
Arguments for
details)