Product specifications

MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–10
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Concise
Configuration
Status
N/A
All
32 bytes (MBT),
48 bytes (BDC),
41 bytes (BUC),
alphanumeric
Query only.
Returns the summarized version of RCS.
Example for MBT-04000 base unit:
<0001/CCS?{cr}
>0001/CCS=aa,bb,cc,dd,e,ff,g,h{cr}{lf}
Where:
aa=Frequency band for Unit 1 BXC (‘C”, ‘X”, ‘Ka’, ‘Ku’, or ‘NA’)
bb=NA
cc=Direction for Unit 1 BXC (‘DN’=BDC, ‘UP’=BUC, ‘NA’=None)
dd=NA
e=Redundancy mode (0, 1, or 2)
ff=Automatic mode
g=Redundancy loop cable address
N=No Cable
A=MBT-A
B=MBT-B
h=External reference lock (1=locked, 0=Not locked)
Example BUC/BDC:
<0001A1/CCS?{cr}{lf}
>0001A1/CCS=aaaaa,bb.bb,c,d.d,e,ff,g,hhhh,i,j,{CR}{lf}
Where:
aaaaa=Frequency in MHz
bb.bb=Attenuation in dB
c=mute state, 0=unmated, 1=muted
d.d=slope adjust
e=LNA current source (BDC only, BUC=X)
ff=LNA current window (BDC only, BUC=XX)
g=LNA fault logic (BDC only, BUC=X)
hhhh=XXXX (reserved for future use)
i=X (reserved for future use)
j=Fault recovery, 0=Manual, 1=Auto
N/A
CCS?
CCS=x….x
(see Description of
Arguments for
details)
Calibrate LNA
Current
CLC=s
MBT
BDC
1 byte, numeric
Command only.
Sets the calibration point for the LNA/LNB current alarm feature in the form
s, where:
s (Source)=1 (LNA A (AUX COMM)) or 2 (LNB Bias Tee)
Example: CLC=2 would record the current measured for the LNB bias tee
CLC=
CLC?
CLC*
CLC!
N/A
N/A