Product specifications

MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–13
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
Query
(Instruction
Code and
qualifier)
Response to
Query
(Target to
Controller)
Operating RF
Frequency
FRE=xxxxx.xxx
BDC
BUC
9 bytes,
numeric
Command or Query
Sets or returns valid Operating RF frequency, in MHz.
For Ku BDCs:
FRE values: 10950-11700 MHz an LO of 10000 MHz is activated
FRE values: 11701-12250 MHz an LO of 10700 MHz is activated
FRE values: 12251-12750 MHz an LO of 11300 MHz is activated
Example: FRE=11300.000
FRE=
FRE?
FRE*
FRE!
FRE?
FRE=xxxxx.xxx
(see Description of
Arguments for
details)
Retreive
Firmware
Number
N/A
All
Query only
Returns the Firmware Number of the unit.
Example: FRW=FW12357’cr’’lf’
N/A
FRW?
FRW=FWxxxxx
Monitor LNA
Current
N/A
MBT
BDC
6 bytes, numeric
Query only.
Returns the LNA/LNB Current Source Level in mA in the form s_xxx.x,
where:
s=1 (LNA A) or 2 (Bias Tee)
xxx.x= LNA Current Source Level in mA
Example:
<0001/LCM?2
>0001/LCM=2_045.3{cr}{lf}
LCM=
LCM?
LCM!
LCM?s
LCM=s_xxx.x
LNA Current
Source
LCS=sx
MBT
BDC
2 bytes, numeric
Command or Query.
Sets or returns LNA Current Source Enable in the form sx, where:
s=1 (LNA A AUX COMM) or 2 (LNB Bias Tee)
x=0 (Disable) or 1 (Enable)
Example: LCS=20 (turns off the LNB Bias Tee current)
LCS=
LCS?)
LCS*
LCS!
LCS?s
LCS=sx
(same format as
command
arguments)
LNA Current
Window
LCW=sxx
MBT
BDC
3 bytes,
numeric
Command or Query.
This command allows the user to set the alarm window in ± % of the
calibrated LNA/LNB Bias Current in the form sxx, where:
s=1 (LNA A AUX COMM) or 2 (LNB Bias Tee)
xx=Valid inputs are 20 to 50 in increments of 1%. Setting the value to 99
disables the alarm function.
Default is Disabled.
Example: LCW=230 sets alarm window for LNB Bias Tee to ± 30%.
LCW=
LCW?
LCW*
LCW!
LCW?s
LCW=sxx
(same format as
command
arguments)